W DOC AIRBUS | AMM A320F

Check of the Electrical Bonding of the Different Components Installed on Composite Materials


TASK 20-28-00-720-008-A
Check of the Electrical Bonding of the Different Components Installed on Composite Materials


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
OHMMETER MULTIRANGE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 20-28-00-869-002-A
Table of the Maximum Permitted Resistance-Values
3. Job Set-up
Subtask 20-28-00-869-066-A
A. Equipment
   (1) Use an OHMMETER MULTIRANGE, with the applicable leads and prods:
  • Set the ohmmeter range to a value that is higher than the maximum permitted value of the assembly that you will measure. Refer to (Ref. AMM TASK 20-28-00-869-002).
  • Set the tension to 500 VDC.
4. Procedure
Subtask 20-28-00-420-086-A
A. Measurement of the Electrical Resistance
CAUTION: MAKE SURE THAT YOU DO NOT CAUSE DAMAGE TO THE EQUIPMENT OR THE STRUCTURE WHEN YOU USE SHARP-POINT PRODS.
CAUTION: MAKE SURE THAT THE TEST EQUIPMENT IS CORRECTLY INSTALLED BEFORE YOU MEASURE THE BONDING VALUES.
   (1) Connect the test equipment at the applicable locations (Ref. AMM TASK 20-28-00-869-002).
     (a) Put one probe on the component.
     (b) Put the other probe on the primary metallic structure.
   (2) Measure the resistance value.
   (3) Make sure that the measured values are not higher than the maximum permitted resistance values (Ref. AMM TASK 20-28-00-869-002).
   (4) Disconnect the test equipment.
5. Close-up
Subtask 20-28-00-942-097-A
A. Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.03.31 23:00:10 UTC