Replenishment of the MLG Torque Link Damper
TASK 12-12-32-611-006-A
Replenishment of the MLG Torque Link Damper
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 12-12-32-941-067-A
Subtask 12-12-32-611-054-A
Subtask 12-12-32-942-066-A
[Rev.10 from 2021]
2026.04.01 12:30:03 UTC
Replenishment of the MLG Torque Link Damper
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CONTAINER 3 L(3/4 USGAL) |
| No specific | AR | GROUND POWER CART-HYDRAULIC |
| No specific | AR | HOSE - BLEED |
| No specific | AR | LOCALLY MANUFACTURED - ANTAGONISTIC CONNECTOR |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SPATULA - NON METALLIC |
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 0.22 and 0.17 m.daN (19.47 and 15.04 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 0.67 and 0.57 m.daN (59.29 and 50.44 lbf.in ) ![]() | |
| 460006804 | 1 | BLEED ADAPTOR |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.02ABA1) | Phosphate Ester Hydraulic Fluid-General Power - - |
| (Material No.06AAB1) | Polysulfide Sealant-General Purpose Fillet - |
| (Material No.08BBF1) | Non Aqueous Cleaner_- Methyl-Ethyl-Ketone - |
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 731 | L.H MAIN GEAR |
| 741 | R.H MAIN GEAR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 32-00-00-481-001-A | Installation of the Safety Devices on the Landing Gears |
Subtask 12-12-32-941-067-A
A. Safety Precautions
(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Make sure that the ground safety locks are on the landing gear (Ref. AMM TASK 32-00-00-481-001).
(3) On the panel 400VU:
4. Procedure(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Make sure that the ground safety locks are on the landing gear (Ref. AMM TASK 32-00-00-481-001).
(3) On the panel 400VU:
- make sure that the landing-gear control-lever 6GA is in the DOWN position
- put a WARNING NOTICE(S) in position to tell persons not to operate the landing gear.
Subtask 12-12-32-611-054-A
A. Replenishment of the MLG Torque Link Damper
(2) Remove and discard the lockwire from the cap assembly (6) and the bleed screw (1).
(3) Clean the items that follow with Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner_- Methyl-Ethyl-Ketone - (Material No.08BBF1) :
(5) Install the 460006804 BLEED ADAPTOR to the bleed plug (2).
(6) Install the HOSE - BLEED on the 460006804 BLEED ADAPTOR.
(7) Put a CONTAINER 3 L(3/4 USGAL) below the bleed hose.
(8) Open the bleed plug (2).
(9) Install a LOCALLY MANUFACTURED - ANTAGONISTIC CONNECTOR to the check valve (7).
(10) Connect a GROUND POWER CART-HYDRAULIC or a hydraulic source (minimum supply pressure 3.45 bar (50 psi)) that contains Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) , to the approved AN connector.
(11) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
(12) Supply hydraulic fluid, at a pressure of between 2.42 bar (35 psi) and 2.75 bar (40 psi), to the check valve (7).
(13) Keep the hydraulic pressure until you get an air-free flow of fluid from the bleed plug (2).
(14) Increase the pressure of the hydraulic fluid to between 2.75 bar (40 psi) and 3.45 bar (50 psi).
(15) Close the bleed plug (2).
(16) Make sure that the reservoir-can (4) moves between 1.5 mm (0.06 in.) and 3.1 mm (0.12 in.) above the FULL level indicator line.
(17) Keep the hydraulic pressure for a time of 3 minutes. During the 3 minutes make sure that:
(20) Measure the quantity of hydraulic fluid that comes out of the check valve (7) during a time of 15 seconds. There must be no more than 15 drops.
(21) Open the bleed plug (2) slowly until the reservoir-can (4) becomes level with the FULL line. Close the bleed plug (2).
(22) If the released hydraulic fluid contains air:
(24) Make sure that the parts retained from the removed component are clean and in the correct condition.
(25) Install the cap assembly (6) on the check valve (7).
(26) Install the bleed screw (1) in the bleed plug (2).
(27) TORQUE the bleed screw (1) to between 0.22 and 0.17 m.daN (19.47 and 15.04 lbf.in )
.
(28) TORQUE the cap assembly (6) to between 0.67 and 0.57 m.daN (59.29 and 50.44 lbf.in )
.
(29) Safety the items that follow with14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - :
5. Close-upWARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) Remove the sealant from the bleed screw (1) and the bleed plug (2) with the SPATULA - NON METALLIC. (2) Remove and discard the lockwire from the cap assembly (6) and the bleed screw (1).
(3) Clean the items that follow with Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner_- Methyl-Ethyl-Ketone - (Material No.08BBF1) :
- The bleed screw (1)
- The bleed plug (2)
- The bleed plug housing (8).
(5) Install the 460006804 BLEED ADAPTOR to the bleed plug (2).
(6) Install the HOSE - BLEED on the 460006804 BLEED ADAPTOR.
(7) Put a CONTAINER 3 L(3/4 USGAL) below the bleed hose.
(8) Open the bleed plug (2).
(9) Install a LOCALLY MANUFACTURED - ANTAGONISTIC CONNECTOR to the check valve (7).
(10) Connect a GROUND POWER CART-HYDRAULIC or a hydraulic source (minimum supply pressure 3.45 bar (50 psi)) that contains Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) , to the approved AN connector.
(11) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
(12) Supply hydraulic fluid, at a pressure of between 2.42 bar (35 psi) and 2.75 bar (40 psi), to the check valve (7).
(13) Keep the hydraulic pressure until you get an air-free flow of fluid from the bleed plug (2).
(14) Increase the pressure of the hydraulic fluid to between 2.75 bar (40 psi) and 3.45 bar (50 psi).
(15) Close the bleed plug (2).
(16) Make sure that the reservoir-can (4) moves between 1.5 mm (0.06 in.) and 3.1 mm (0.12 in.) above the FULL level indicator line.
(17) Keep the hydraulic pressure for a time of 3 minutes. During the 3 minutes make sure that:
- No external leakage of fluid occurs
- The reservoir-can (4) does not move.
- Slowly open the bleed plug (2) to release the hydraulic pressure
- Do steps (9) thru (14) again.
(20) Measure the quantity of hydraulic fluid that comes out of the check valve (7) during a time of 15 seconds. There must be no more than 15 drops.
(21) Open the bleed plug (2) slowly until the reservoir-can (4) becomes level with the FULL line. Close the bleed plug (2).
(22) If the released hydraulic fluid contains air:
- Slowly open the bleed plug (2) to release the hydraulic pressure
- Do steps (9) thru (18) again.
(24) Make sure that the parts retained from the removed component are clean and in the correct condition.
(25) Install the cap assembly (6) on the check valve (7).
(26) Install the bleed screw (1) in the bleed plug (2).
(27) TORQUE the bleed screw (1) to between 0.22 and 0.17 m.daN (19.47 and 15.04 lbf.in )
. (28) TORQUE the cap assembly (6) to between 0.67 and 0.57 m.daN (59.29 and 50.44 lbf.in )
. (29) Safety the items that follow with
- The bleed screw (1) to the piston assembly (3)
- The cap assembly (6) to the adjacent bolt (5).
- The bleed screw (1)
- The bleed plug (2)
- The bleed plug housing (8).
Subtask 12-12-32-942-066-A
A. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the SAFETY BARRIER(S).
(3) Remove the WARNING NOTICE(S).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the SAFETY BARRIER(S).
(3) Remove the WARNING NOTICE(S).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.