Removal of the Engine Leasing-Plate Mount Assembly
TASK 11-24-71-000-804-A
Removal of the Engine Leasing-Plate Mount Assembly
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 11-24-71-941-056-A ** ON A/C NOT FOR ALL
Subtask 11-24-71-020-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 22:54:14 UTC
Removal of the Engine Leasing-Plate Mount Assembly
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 430 | ENG 1 AIR INTAKE, FAN AND ACCESS GEARBOX |
| 440 | ENG 2 AIR INTAKE, FAN AND ACCESS GEARBOX |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 11-00-00-960-002-A | Replacement of the Engine Leasing Plate |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
Subtask 11-24-71-941-056-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start engine 1(2).
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 11-24-71-040-054-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on ENG panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start engine 1(2).
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Deactivation of the Thrust Reverser
Subtask 11-24-71-010-057-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-012). C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL
(b) FOR [1000EM2] (ENGINE-2)
447AL.
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL
(b) FOR [1000EM2] (ENGINE-2)
447AL.
Subtask 11-24-71-020-054-A ** ON A/C NOT FOR ALL
A. Removal of the Engine Leasing-Plate Mount Assembly
(1) Remove the engine leasing plate (Ref. AMM TASK 11-00-00-960-002).
(2) Remove the bolts (1) and the nuts (2).
(3) Remove the leasing plate mount (3) from the engine flange.
(1) Remove the engine leasing plate (Ref. AMM TASK 11-00-00-960-002).
(2) Remove the bolts (1) and the nuts (2).
(3) Remove the leasing plate mount (3) from the engine flange.
Engine Leasing-Plate Mount Assembly