GENERAL VISUAL INSPECTION OF EMERGENCY EXITS INCLUDING DOOR SURROUND ON FUSELAGE AND DOOR SEALS, EXTERNAL SURFACE (EWIS)
TASK 05-28-30-200-013-A
GENERAL VISUAL INSPECTION OF EMERGENCY EXITS INCLUDING DOOR SURROUND ON FUSELAGE AND DOOR SEALS, EXTERNAL SURFACE (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-834-05
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-28-30-010-058-A ** ON A/C NOT FOR ALL
Subtask 05-28-30-210-062-A ** ON A/C NOT FOR ALL
Subtask 05-28-30-410-058-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2017]
2026.03.31 22:51:12 UTC
GENERAL VISUAL INSPECTION OF EMERGENCY EXITS INCLUDING DOOR SURROUND ON FUSELAGE AND DOOR SEALS, EXTERNAL SURFACE (EWIS)
1. Reason for the Job
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 834 | EMERGENCY EXITS |
| 844 | EMERGENCY EXITS |
| 834, 844 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-21-11-000-001-A | Removal of the Emergency Exit Hatch |
| TASK 52-21-11-400-001-A | Installation of the Emergency Exit Hatch |
Subtask 05-28-30-010-058-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zone 834(844).
(2) Remove the emergency exit hatches 834 844 (Ref. AMM TASK 52-21-11-000-001).
4. Procedure(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zone 834(844).
(2) Remove the emergency exit hatches 834 844 (Ref. AMM TASK 52-21-11-000-001).
Subtask 05-28-30-210-062-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a general visual inspection of the emergency exits. This inspection includes the door surround on the fuselage, the door seals and the external surface of the door.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations are attached correctly.
5. Close-up(1) Do a general visual inspection of the emergency exits. This inspection includes the door surround on the fuselage, the door seals and the external surface of the door.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations are attached correctly.
Subtask 05-28-30-410-058-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Install the emergency exit hatches 834 844 (Ref. AMM TASK 52-21-11-400-001).
(2) Remove the access platform(s).
(1) Install the emergency exit hatches 834 844 (Ref. AMM TASK 52-21-11-400-001).
(2) Remove the access platform(s).