GENERAL VISUAL INSPECTION OF TAIL CONE APU AND ACCESSORY COMPARTMENT (EWIS)
TASK 05-23-10-200-003-A
GENERAL VISUAL INSPECTION OF TAIL CONE APU AND ACCESSORY COMPARTMENT (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-315-01
GENERAL VISUAL INSPECTION OF TAIL CONE APU AND ACCESSORY COMPARTMENT (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-23-10-010-052-A
Subtask 05-23-10-210-052-A
Subtask 05-23-10-410-052-A
[Rev.10 from 2021]
2026.03.31 22:49:29 UTC
GENERAL VISUAL INSPECTION OF TAIL CONE APU AND ACCESSORY COMPARTMENT (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-315-01
GENERAL VISUAL INSPECTION OF TAIL CONE APU AND ACCESSORY COMPARTMENT (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 315 | TAIL CONE APU AND ACCESSORY COMPARTMENT |
| 316 | TAIL CONE APU AND ACCESSORY COMPARTMENT |
| 315AL, 316AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-001-A | Open the APU Doors for Access |
| TASK 52-41-00-410-001-A | Close the APU Doors after Access |
Subtask 05-23-10-010-052-A
A. Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the zone 310.
(2) Open the access doors:
315AL 316AR.
(Ref. AMM TASK 52-41-00-010-001)
4. Procedure(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the zone 310.
(2) Open the access doors:
315AL 316AR.
(Ref. AMM TASK 52-41-00-010-001)
Subtask 05-23-10-210-052-A
A. Inspection
(1) Do a general visual inspection of the tail cone Auxiliary Power Unit (APU) and accessory compartment.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting, piping) are attached correctly.
5. Close-up(1) Do a general visual inspection of the tail cone Auxiliary Power Unit (APU) and accessory compartment.
(2) Make sure that there are no signs of corrosion, cracks or damage.
(3) Make sure that all the installations (wiring, ducting, piping) are attached correctly.
Subtask 05-23-10-410-052-A
A. Close Access
(1) Close the access doors:
315AL 316AR.
(Ref. AMM TASK 52-41-00-410-001)
(2) Remove the access platform(s).
(1) Close the access doors:
315AL 316AR.
(Ref. AMM TASK 52-41-00-410-001)
(2) Remove the access platform(s).