W DOC AIRBUS | AMM A320F

36-13 GROUND COMPRESSED AIR SUPPLY SYSTEM


    36-13-00 GROUND COMPRESSED AIR SUPPLY SYSTEM

  • PB.001 GROUND COMPRESSED AIR SUPPLY SYSTEM - DESCRIPTION AND OPERATION
  • PB.001 CONF:[21] GROUND COMPRESSED AIR SUPPLY SYSTEM - DESCRIPTION AND OPERATION
  • PB.001 CONF:[03] GROUND COMPRESSED AIR SUPPLY SYSTEM - DESCRIPTION AND OPERATION
  • PB.201 GROUND COMPRESSED AIR SUPPLY SYSTEM - MAINTENANCE PRACTICES
    • 36-13-00-615-801-A [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1) with the HP Ground Source
    • 36-13-00-615-801-A-01 [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA2) with the HP Ground Source
    • 36-13-00-615-801-A-02 [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1, 4000HA2) with the HP Ground Source
    • 36-13-00-615-804-A [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at the APU Load-Compressor Valve with the HP Ground Source
  • PB.201 CONF:[21] GROUND COMPRESSED AIR SUPPLY SYSTEM - MAINTENANCE PRACTICES
    • 36-13-00-615-803-A [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1) with the HP Ground Source
    • 36-13-00-615-803-A-01 [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA2) with the HP Ground Source
    • 36-13-00-615-803-A-02 [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at the Pressure Regulating Valve (PRV) (4000HA1, 4000HA2) with the HP Ground Source
    • 36-13-00-615-806-A [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at the APU Load-Compressor Valve with the HP Ground Source
  • PB.201 CONF:[03] GROUND COMPRESSED AIR SUPPLY SYSTEM - MAINTENANCE PRACTICES
    • 36-13-00-615-802-A [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at the Pressure Regulating Valve (PRV) (4000HA1) with the HP Ground Source
    • 36-13-00-615-802-A-01 [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA2) with the HP Ground Source
    • 36-13-00-615-802-A-02 [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at the Pressure Regulating Valve (PRV) (4000HA1, 4000HA2) with the HP Ground Source
    • 36-13-00-615-805-A [10]
      Decontamination of the Bleed-Air Ducting System Disconnected at the APU Load-Compressor Valve with the HP Ground Source
  • 36-13-41 GROUND CONNECTOR - HP

  • PB.401 GROUND CONNECTOR - HP - REMOVAL/INSTALLATION