W DOC AIRBUS | AMM A320F

Installation of the HP Ground Connector


TASK 36-13-41-400-001-A
Installation of the HP Ground Connector


WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
FIN: 7300HM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
Torque wrench: range to between 0.8 and 0.7 m.daN (70.80 and 61.95 lbf.in ) T
No specific
Torque wrench: range to between 1.06 and 0.82 m.daN (93.81 and 72.57 lbf.in ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
191BB
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
1
NUT
AIPC 36-11-03-22-060
1
NUT
AIPC 36-11-83-03-190
 D. Referenced Information
REFERENCE
DESIGNATION
F HP Ground Connector 7300HM ** ON A/C NOT FOR ALL
F HP Ground Connector 7300HM ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 36-13-41-860-051-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the WARNING NOTICE(S) are in position:
  • in the cockpit on the Engine Control Panel 115VU to tell persons not to start the engine(s),
  • in the cockpit on the AIR COND Overhead Control Panel 30VU to tell persons not to push in the APU BLEED pushbutton switch.
   (2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position below the access panel 191BB.
   (3) Make sure that the access panel 191BB is open.
Subtask 36-13-41-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
** ON A/C ALL
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 2/MONG3HA2D12
49VUAIR BLEED/ENG 1/CTL2HA1D11
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
** ON A/C ALL
122VUAIR BLEED/X FEED VALVE/NORM1HVZ20
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 1/MONG3HA1Z23
122VUAIR BLEED/ENG 2/CTL2HA2Z22
4. Procedure
Subtask 36-13-41-420-050-B ** ON A/C NOT FOR ALL
A. Installation of the HP Ground Connector
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the blanking cap from the duct.
   (4) Install the O-ring (4) and the check valve (5) in the HP Ground Connector (3).
   (5) Install the sealing ring (6) and the HP Ground Connector (3) with four washers (2) and the AIPC 36-11-03-22-060 NUT (1) at the long bolts and with one washer (2) and the AIPC 36-11-03-22-060 NUT (1) at the short bolts.
   (6) TORQUE the nuts (1) to between 1.06 and 0.82 m.daN (93.81 and 72.57 lbf.in )
T.
Subtask 36-13-41-420-050-C ** ON A/C NOT FOR ALL Subtask 36-13-41-420-050-D ** ON A/C NOT FOR ALL Subtask 36-13-41-420-050-E ** ON A/C NOT FOR ALL 5. Close-up
Subtask 36-13-41-410-050-A
Subtask 36-13-41-865-052-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
** ON A/C ALL
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 2/MONG3HA2D12
49VUAIR BLEED/ENG 1/CTL2HA1D11
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
** ON A/C ALL
122VUAIR BLEED/X FEED VALVE/NORM1HVZ20
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 1/MONG3HA1Z23
122VUAIR BLEED/ENG 2/CTL2HA2Z22
[Rev.10 from 2021] 2026.04.01 01:16:07 UTC