21-51 FLOW CONTROL AND INDICATING
- PB.001 FLOW CONTROL AND INDICATING - DESCRIPTION AND OPERATION
- PB.401 FLOW CONTROL AND INDICATING - DEACTIVATION/REACTIVATION
-
21-51-00-040-001-A
[10]
Deactivation of the Pack Flow-Control Valve -
21-51-00-440-001-A
[10]
Reactivation of the Pack Flow-Control Valve -
21-51-00-040-002-A
[10]
Deactivation of the Air Conditioning Pack -
21-51-00-440-002-A
[10]
Reactivation of the Air Conditioning Pack
-
21-51-00-040-001-A
[10]
- PB.501 FLOW CONTROL AND INDICATING - ADJUSTMENT/TEST
-
21-51-00-710-002-A
[10]
Operational Test of the Flow Control and Indicating System -
21-51-00-710-003-A
[10]
Operational Test of the Flow Control Valves Closing
-
21-51-00-710-002-A
[10]
- PB.601 FLOW CONTROL AND INDICATING - INSPECTION/CHECK
-
21-51-00-200-001-A
[10]
Delta P Sense Lines Torque Check and Inspection
-
21-51-00-200-001-A
[10]
- PB.801 FLOW CONTROL AND INDICATING - REPAIRS
-
21-51-00-300-001-A
[10]
Attachment Components - Repair/Replacement
-
21-51-00-300-001-A
[10]
- PB.401 SENSOR - PRESSURE - REMOVAL/INSTALLATION
-
21-51-11-000-001-A
[10]
Removal of the Differential Pressure Sensor -
21-51-11-400-001-A
[10]
Installation of the Differential Pressure Sensor
-
21-51-11-000-001-A
[10]
- PB.401 SENSOR - PACK INLET PRESSURE - REMOVAL/INSTALLATION
-
21-51-13-000-001-A
[10]
Removal of the Pack-Inlet Pressure Sensor -
21-51-13-400-001-A
[10]
Installation of the Pack-Inlet Pressure Sensor
-
21-51-13-000-001-A
[10]
- PB.401 FILTER - OZONE - REMOVAL/INSTALLATION
-
21-51-41-000-001-A
[10]
Removal of the Ozone Filter -
21-51-41-400-001-A
[10]
Installation of the Ozone Filter -
21-51-41-920-001-A
[10]
Remove Ozone Filter (Converter) for in Shop Functional Check
-
21-51-41-000-001-A
[10]
- PB.601 FILTER - OZONE - INSPECTION/CHECK
-
21-51-41-200-001-A
[10]
Attachment Components (In-Service Wear Limits) - Ozone Filter
-
21-51-41-200-001-A
[10]
- PB.301 VALVE - PACK FLOW CONTROL - SERVICING
-
21-51-51-600-001-A
[10]
Scheduled Replacement of the Trailing-Edge Probe Filter of the Pack Flow-Control Valve
-
21-51-51-600-001-A
[10]
- PB.401 VALVE - PACK FLOW CONTROL - REMOVAL/INSTALLATION
-
21-51-51-000-001-A
[10]
Removal of the Pack Flow-Control Valve/ Pack Flow-Control Unit -
21-51-51-400-001-A
[10]
Installation of the Pack Flow-Control Valve/Pack Flow-Control Unit -
21-51-51-000-002-B
[9]
Removal of the Air Duct upstream of the Flow Control Unit -
21-51-51-400-002-B
[9]
Installation of the Air Duct upstream of the Flow Control Unit
-
21-51-51-000-001-A
[10]
- PB.601 VALVE - PACK FLOW CONTROL - INSPECTION/CHECK
-
21-51-51-200-001-A
[10]
Attachment Components (In-Service Wear Limits) - Flow Control Valve (Unit) -
21-51-51-200-002-A
[10]
Attachment Components (In-Service Wear Limits) - Air Duct
-
21-51-51-200-001-A
[10]
- PB.401 ACTUATOR - MIXER FLAP - REMOVAL/INSTALLATION
-
21-51-52-000-001-A
[10]
Removal of the Mixer Flap Actuator -
21-51-52-400-001-A
[10]
Installation of the Mixer Flap Actuator
-
21-51-52-000-001-A
[10]