Operation Time for the Starter More Than the Limits, on Engine 1 or 2
TASK 80-00-00-810-831-A
Operation Time for the Starter More Than the Limits, on Engine 1 or 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 80-00-00-710-113-A ** ON A/C NOT FOR ALL
Subtask 80-00-00-810-092-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:38:37 UTC
Operation Time for the Starter More Than the Limits, on Engine 1 or 2
1. Possible Causes
- pneumatic starter
- starter shutoff valve
- ECU [4000KS]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 71-00-00-710-003 | Engine Automatic Start |
| AMM 73-21-60-000-001 | Removal of the Electronic Control Unit (ECU) |
| AMM 73-21-60-400-001 | Installation of the Electronic Control Unit (ECU) |
| AMM 73-29-00-710-040 | Operational Test of the FADEC on the ground (with Engine Motoring) |
| AMM 80-11-10-000-001 | Removal of the Pneumatic Starter |
| AMM 80-11-10-000-002 | Removal of the Pneumatic Starter |
| AMM 80-11-10-400-001 | Installation of the Pneumatic Starter |
| AMM 80-11-10-400-002 | Installation of the Pneumatic Starter |
| AMM 80-11-20-000-001 | Removal of the Starter Shutoff Valve |
| AMM 80-11-20-400-001 | Installation of the Starter Shutoff Valve |
Subtask 80-00-00-710-113-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the operational test of the FADEC on the ground (wirh engine non motoring) AMM 73-29-00-710-040.
4. Fault Isolation(1) Do the operational test of the FADEC on the ground (wirh engine non motoring) AMM 73-29-00-710-040.
Subtask 80-00-00-810-092-A ** ON A/C NOT FOR ALL
A. If the test does not give a maintenance message:
Subtask 80-00-00-810-092-B ** ON A/C NOT FOR ALL - on the lower ECAM display unit, do a check for low pressure in the starter air duct (at least 30 PSIG)
- replace the pneumatic starter AMM 80-11-10-000-001 and AMM 80-11-10-400-001.
- replace the starter shutoff valve AMM 80-11-20-000-001 and AMM 80-11-20-400-001.
- replace the ECU [4000KS] AMM 73-21-60-000-001 and AMM 73-21-60-400-001.
A. If the test does not give a maintenance message:
Subtask 80-00-00-710-114-A ** ON A/C NOT FOR ALL - on the lower ECAM display unit, do a check for low pressure in the starter air duct (at least 30 PSIG)
- replace the pneumatic starter AMM 80-11-10-000-002 and AMM 80-11-10-400-002.
- replace the ECU [4000KS] AMM 73-21-60-000-001 and AMM 73-21-60-400-001.