W DOC AIRBUS | TSM A320F

No N1 Rotation during Engine 1 Start



1. Possible Causes
· wiring
· EEC ( 4000KS )
2 Job Set-up Information
A. Referenced Information
REFERENCE DESIGNATION
Ref. AMM 72-00-00-200-012 Borescope Inspection of the LP Turbine
Ref. AMM 72-00-00-200-017 Inspection of the LP Compressor
Ref. AMM 73-22-34-000-010 Removal of the Electronic Engine Control (EEC)
Ref. AMM 73-22-34-400-010 Installation of the Electronic Engine Control (EEC)
Ref. ASM 73-25-13
Ref. AMM 77-11-00-860-010 Change over the N1 Rotational Speed Indicating Probe Harness Leads
400VS-1, 400VS-2, 400VS-5 and 400VS-6
3. Fault Confirmation
Subtask 80-00-00-710-141-A
A. Test
Not applicable, the fault is evident.
4. Fault Isolation
Subtask 80-00-00-810-111-A
A. If the fault is identified by the ECAM warning ENG 1 START FAULT
- NO N1 ROTATION:
(1) Turn the N1 fan manually in a clockwise or counterclockwise direction.
(a) If the fan turns freely:
· change over the speed probe harness leads Ref. AMM 77-11-00-860-010 .
(b) If the fault continues (for channel A):
· do a check and repair the wiring from the EEC (4000KS) to N1 terminal block connector
(4000VS): pins J2/L, d to pins 1, 2 Ref. ASM 73-25-13.
(c) If the fault continues (for channel B):
· do a check and repair the wiring from the EEC (4000KS) to N1 terminal block connector
(4000VS): pins J8/L, d to pins 5, 6 Ref. ASM 73-25-13.
(d) If the fault continues:
· replace the EEC ( 4000KS ) Ref. AMM 73-22-34-000-010 and Ref. AMM 73-22-34-400-010 .
(2) If the fan does not turn freely:
(a) do an inspection of the LP compressor Ref. AMM 72-00-00-200-017 and the LP turbine Ref.
AMM 72-00-00-200-012 .