W DOC AIRBUS | TSM A320F

Failure of the Oil Quantity Transmitter on Engine 2


TASK 79-31-00-810-808-A
Failure of the Oil Quantity Transmitter on Engine 2


1. Possible Causes
  • XMTR-OIL QTY [4002EN]
  • wiring from the oil quantity transmitter (4002EN) pins A/3, 4 to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
AMM 79-31-15-000-040
Removal of the Oil Quantity Transmitter
AMM 79-31-15-000-041
Removal of the Oil Quantity Transmitter
AMM 79-31-15-400-040
Installation of the Oil Quantity Transmitter
AMM 79-31-15-400-041
Installation of the Oil Quantity Transmitter
ASM 793601
3. Fault Confirmation
Subtask 79-31-00-865-053-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/OIL/QTY1EN2N41
Subtask 79-31-00-710-060-A ** ON A/C NOT FOR ALL
B. Do the operational test of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 79-31-00-810-055-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : ENG2 OIL QTY XMTR 4002EN:
   (1) If the fault continues:
  • do a check and repair the wiring from the oil quantity transmitter (4002EN) pins A/3, 4 to the first terminal block ASM 793601 and ASM 793601.
Subtask 79-31-00-810-055-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : ENG2 OIL QTY XMTR 4002EN:
   (1) If the fault continues:
  • do a check and repair the wiring from the oil quantity transmitter (4002EN) pins A/3, 4 to the first terminal block ASM 793601 and ASM 793601.
Subtask 79-31-00-710-061-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.