W DOC AIRBUS | TSM A320F

Failure of the Oil Quantity Transmitter on Engine 1


TASK 79-31-00-810-805-A
Failure of the Oil Quantity Transmitter on Engine 1


1. Possible Causes
  • XMTR-OIL QTY [4002EN]
  • wiring from the oil quantity transmitter (4002EN) pins A/3,4 to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
AMM 79-31-15-000-040
Removal of the Oil Quantity Transmitter
AMM 79-31-15-000-041
Removal of the Oil Quantity Transmitter
AMM 79-31-15-400-040
Installation of the Oil Quantity Transmitter
AMM 79-31-15-400-041
Installation of the Oil Quantity Transmitter
ASM 793601
3. Fault Confirmation
Subtask 79-31-00-865-052-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUENGINE/ENG1/OIL/QTY1EN1N39
Subtask 79-31-00-710-058-A ** ON A/C NOT FOR ALL
B. Do the operational test of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 79-31-00-810-054-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : ENG1 OIL QTY XMTR 4002EN:
   (1) If the fault continues:
  • do a check and repair the wiring from the oil quantity transmitter (4002EN) pins A/3,4 to the first terminal block ASM 793601 and ASM 793601.
Subtask 79-31-00-810-054-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC1 : ENG1 OIL QTY XMTR 4002EN:
   (1) If the fault continues:
  • do a check and repair the wiring from the oil quantity transmitter (4002EN) pins A/3,4 to the first terminal block ASM 793601 and ASM 793601.
Subtask 79-31-00-710-059-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:38:23 UTC