W DOC AIRBUS | TSM A320F

VORV LVDT Electrical Failure on Channel A and B


TASK 79-21-00-810-841-A
VORV LVDT Electrical Failure on Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 79-21-00-810-820-A
VORV LVDT Electrical Failure Channel B
TSM TASK 79-21-00-810-839-A
VORV LVDT Electrical Failure on Channel A
3. Fault Confirmation
Subtask 79-21-00-710-090-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 79-21-00-810-092-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 79-21-00-810-839).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 79-21-00-810-820).
5. Close-up
Subtask 79-21-00-860-080-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:38:36 UTC