W DOC AIRBUS | TSM A320F

Loss of the Oil Pressure Indication on Engine 1 or 2


TASK 79-00-00-810-824-A
Loss of the Oil Pressure Indication on Engine 1 or 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
AMM 79-33-15-000-040
Removal of the Oil Pressure Transmitter
AMM 79-33-15-000-041
Removal of the Oil Pressure Transmitter
AMM 79-33-15-400-040
Installation of the Oil Pressure Transmitter
AMM 79-33-15-400-041
Installation of the Oil Pressure Transmitter
ASM 793601
3. Fault Confirmation
Subtask 79-00-00-710-096-A ** ON A/C NOT FOR ALL
A. Test
   (1) Not applicable.
4. Fault Isolation
Subtask 79-00-00-865-053-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUENGINE/ENG1/OIL/PRESS2EN1N40
Subtask 79-00-00-810-082-A ** ON A/C NOT FOR ALL
B. Replace the XMTR-OIL PRESS [4003EN] AMM 79-33-15-000-040 and AMM 79-33-15-400-040.
   (1) If the fault continues:
  • do a check of the electrical wiring between the ENG1(2) OIL PRESS XMTR (4003EN), the EIU-1 [1KS1] ( EIU-2 [1KS2] ), the SDAC1 and the SDAC2 ASM 793601.
   (2) If the fault continues:
  • do a check of the electrical grounding of the ENG1(2) OIL PRESS XMTR (4003EN) at the ground terminal on the engine fan case ASM 793601.
   (3) If the fault continues:
  • do a check of the electrical wiring between the ENG1(2) OIL PRESS XMTR (4003EN) and circuit breaker 2EN1(2) ASM 793601,
  • repair wiring or replace circuit breaker as required.
  • repair wiring or replace circuit breaker as required.
   (4) If the fault continues:
   (5) If the fault continues:
   (6) If the fault continues:
Subtask 79-00-00-810-082-B ** ON A/C NOT FOR ALL
B. Replace the XMTR-OIL PRESS [4003EN] AMM 79-33-15-000-041 and AMM 79-33-15-400-041.
   (1) If the fault continues:
  • do a check of the electrical wiring between the ENG1(2) OIL PRESS XMTR (4003EN), the EIU-1 [1KS1] ( EIU-2 [1KS2] ), the SDAC1 and the SDAC2 ASM 793601.
   (2) If the fault continues:
  • do a check of the electrical grounding of the ENG1(2) OIL PRESS XMTR (4003EN) at the ground terminal on the engine fan case ASM 793601.
   (3) If the fault continues:
  • do a check of the electrical wiring between the ENG1(2) OIL PRESS XMTR (4003EN) and circuit breaker 2EN1(2) ASM 793601,
  • repair wiring or replace circuit breaker as required.
   (4) If the fault continues:
   (5) If the fault continues:
   (6) If the fault continues:
Subtask 79-00-00-710-097-A ** ON A/C NOT FOR ALL
C. No additional maintenance action is required if the fault is not confirmed.
   (1) Repeat the fault isolation procedure if the fault continues.