Oil Quantity Indication Replaced by Amber XX/Loss or fluctuation of the Oil Quantity Indication on Engine 1 or 2
TASK 79-00-00-810-812-A
Oil Quantity Indication Replaced by Amber XX/Loss or fluctuation of the Oil Quantity Indication on Engine 1 or 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 79-00-00-710-072-A ** ON A/C NOT FOR ALL
Subtask 79-00-00-865-052-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:38:21 UTC
Oil Quantity Indication Replaced by Amber XX/Loss or fluctuation of the Oil Quantity Indication on Engine 1 or 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
| AMM 73-25-34-000-040 | Removal of the Engine Interface Unit (EIU) |
| AMM 73-25-34-400-040 | Installation of the Engine Interface Unit (EIU) |
| AMM 79-31-15-000-040 | Removal of the Oil Quantity Transmitter |
| AMM 79-31-15-000-041 | Removal of the Oil Quantity Transmitter |
| AMM 79-31-15-400-040 | Installation of the Oil Quantity Transmitter |
| AMM 79-31-15-400-041 | Installation of the Oil Quantity Transmitter |
| ASM 793601 |
Subtask 79-00-00-710-072-A ** ON A/C NOT FOR ALL
A. Test
(1) Not applicable.
4. Fault Isolation(1) Not applicable.
NOTE: It is normal that the oil quantity indication displayed on the ECAM can be subjected to variations/fluctuations. This phenomenon linked to gulping of oil in the tank is sensible during engine start, after engine power significant variations (ie TOGA), in that case it is inappropriate to perform trouble shooting for oil quantity indication failure. In the opposite, if the variations/fluctuations are experienced on ground when engine is not running or for engine stabilized operation, trouble shooting has to be performed.
Subtask 79-00-00-865-052-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 79-00-00-810-064-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG2/OIL/QTY | 1EN2 | N41 |
| 121VU | ENGINE/ENG1/OIL/QTY | 1EN1 | N39 |
B. Replace the XMTR-OIL QTY [4002EN] AMM 79-31-15-000-040 and AMM 79-31-15-400-040.
(1) If the fault continues:
Subtask 79-00-00-810-064-B ** ON A/C NOT FOR ALL (1) If the fault continues:
- do a check and repair the electrical wiring between the oil quantity transmitter (4002EN), the EIU1(2) (1KS1(2)), the SDAC1 and the SDAC2 ASM 793601.
- do a check of the electrical grounding of the oil quantity transmitter (4002EN) at the ground terminal on engine fan case ASM 793601.
- do a check of the electrical wiring between the oil quantity transmitter (4002EN) and the circuit breaker 1EN1 or 1EN2 ASM 793601.
- repair the wiring or replace the circuit breaker as required.
- replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001
- replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001
- replace the EIU-1 [1KS1] ( EIU-2 [1KS2] ) AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
B. Replace the XMTR-OIL QTY [4002EN] AMM 79-31-15-000-041 and AMM 79-31-15-400-041.
(1) If the fault continues:
Subtask 79-00-00-710-073-A ** ON A/C NOT FOR ALL (1) If the fault continues:
- do a check and repair the electrical wiring between the oil quantity transmitter (4002EN), the EIU1(2) (1KS1(2)), the SDAC1 and the SDAC2 ASM 793601.
- do a check of the electrical grounding of the oil quantity transmitter (4002EN) at the ground terminal on engine fan case ASM 793601.
- do a check of the electrical wiring between the oil quantity transmitter (4002EN) and the circuit breaker 1EN1 or 1EN2 ASM 793601.
- repair the wiring or replace the circuit breaker as required.
- replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001
- replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001
- repair the wiring or replace the circuit breaker as required.
- replace the EIU-1 [1KS1] ( EIU-2 [1KS2] ) AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
C. No additional maintenance action is required if the fault is not confirmed.
(1) Repeat the fault isolation procedure if the fault continues.