W DOC AIRBUS | TSM A320F

Left Track Lock Proximity Switch Signal Failure on Channel A and B


TASK 78-31-00-810-A50-A
Left Track Lock Proximity Switch Signal Failure on Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 78-31-00-810-955-A
Left Track Lock Proximity Switch Signal Failure on Channel A
TSM TASK 78-31-00-810-956-A
Left Track Lock Proximity Switch Signal Failure on Channel B
3. Fault Confirmation
Subtask 78-31-00-710-364-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 78-31-00-810-468-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 78-31-00-810-955).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 78-31-00-810-956).
5. Close-up
Subtask 78-31-00-860-157-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:38:20 UTC