W DOC AIRBUS | TSM A320F

Right Hand Upper Locking Feedback Actuator Proximity Switch Signal Failure on Channel A and B


TASK 78-31-00-810-A45-A
Right Hand Upper Locking Feedback Actuator Proximity Switch Signal Failure on Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 78-31-00-810-947-A
Right Hand Upper Locking Feedback Actuator Proximity Switch Signal Failure on Channel A
TSM TASK 78-31-00-810-948-A
Right Hand Upper Locking Feedback Actuator Proximity Switch Signal Failure on Channel B
3. Fault Confirmation
Subtask 78-31-00-710-359-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 78-31-00-810-463-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 78-31-00-810-947).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 78-31-00-810-948).
5. Close-up
Subtask 78-31-00-860-152-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:38:19 UTC