W DOC AIRBUS | TSM A320F

Left TLV Failed Open


TASK 78-31-00-810-986-A
Left TLV Failed Open


1. Possible Causes
  • RELAY-THRUST REVERSER LOCKING POWER (2EG)
  • LH TRAS LOCK VALVE [4141KS]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 71-00-00-810-843-A
Nacelle Component and Harness Troubleshooting Procedure for Guidance Troubleshooting Intermittent Faults
AMM 78-31-00-710-805
Operational Test of Thrust Reverser with MCDU
AWM 783601
AWM 783602
AMM 78-37-02-000-801
Removal of the TRAS Track Lock Valve
AMM 78-37-02-400-801
Installation of the TRAS Track Lock Valve
3. Fault Confirmation
Subtask 78-31-00-865-058-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers referred to in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1)
121VUENG1/REV/LOCK1EG1N44
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2)
121VUENG2/REV/LOCK1EG2N45
Subtask 78-31-00-710-301-A ** ON A/C NOT FOR ALL
B. Do the operational test of the thrust reverser with the MCDU to confirm this fault AMM 78-31-00-710-805.
   (1) If the maintenance message does not come back, troubleshoot as described in the nacelle component and harness troubleshooting procedure for guidance troubleshooting intermittent faults (Ref. TSM TASK 71-00-00-810-843).
     (a) Monitor the engine for reoccurring maintenance message.
   (2) If the maintenance message comes back (hard fault), go to the Para. Fault Isolation.
4. Fault Isolation
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS WARNING, INJURY CAN OCCUR.
Subtask 78-31-00-810-330-A ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
   (1) Check if same fault comes on also on right side:
     (a) If yes:
       1 Open, safety and tag the circuit breaker 1EG1 for fault on ENG 1 or 1EG2 for fault on ENG 2.
       2 Replace RELAY-THRUST REVERSER LOCKING POWER (2EG);
         a For fault on ENG 1, refer to AWM 783601.
         b For fault on ENG 2, refer to AWM 783602.
       3 Remove the safety clips and tags and close the circuit breaker 1EG1 for fault on ENG 1 or 1EG2 for fault on ENG 2.
     (b) If no:
       1 Replace LH TRAS LOCK VALVE [4141KS] AMM 78-37-02-000-801 and AMM 78-37-02-400-801.
       2 Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:38:18 UTC