Pressure Proximity Switch Signal Failure on Channel A


TASK 78-31-00-810-944-A
Pressure Proximity Switch Signal Failure on Channel A


1. Possible Causes
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
PLIERS - JAWED, SOFT
 B. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 71-00-00-810-843-A
Nacelle Component and Harness Troubleshooting Procedure for Guidance Troubleshooting Intermittent Faults
AMM 71-13-00-010-802
Opening of the Fan Cowl Doors
AMM 71-13-00-410-802
Closing of the Fan Cowl Doors
AWM 715135
AMM 73-21-01-000-801
Removal of the Electronic Engine Control (EEC)
AMM 73-21-01-400-801
Installation of the Electronic Engine Control (EEC)
AMM 73-21-62-000-802
Removal of the EEC Wiring Harness (WF02)
AMM 73-21-62-400-802
Installation of the EEC Wiring Harness (WF02)
AMM 78-31-00-210-802
General Visual Inspection (GVI) of the Proximity Sensor Targets
AMM 78-31-00-710-805
Operational Test of Thrust Reverser with MCDU
AMM 78-31-01-000-801
Removal of the TRAS Hydraulic Control Unit (HCU)
AMM 78-31-01-400-801
Installation of the TRAS Hydraulic Control Unit (HCU)
AMM 78-31-21-000-801
Removal of the Hydraulic Control Unit (HCU) Pressure Switch
AMM 78-31-21-400-801
Installation of the Hydraulic Control Unit (HCU) Pressure Switch
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
AWM 783611
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
AWM 783612
3. Fault Confirmation
Subtask 78-31-00-710-259-A ** ON A/C NOT FOR ALL
A. Do the operational test of the thrust reverser with the MCDU to confirm this fault AMM 78-31-00-710-805.
   (1) If the maintenance message does not come back, troubleshoot as described in the nacelle component and harness troubleshooting procedure for guidance troubleshooting intermittent faults (Ref. TSM TASK 71-00-00-810-843).
     (a) Monitor the engine reoccurring maintenance message.
   (2) If the maintenance message comes back (hard fault), go to the Para. Fault Isolation.
4. Fault Isolation
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS WARNING, INJURY CAN OCCUR.
CAUTION: MAKE SURE YOU REMOVE ELECTRICAL POWER FROM THE EEC BEFORE YOU REMOVE THE ELECTRICAL CONNECTORS. IF YOU DO NOT OBEY THIS INSTRUCTION, DAMAGE TO THE EEC CAN OCCUR.
Subtask 78-31-00-810-288-A ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
   (1) Get access to HCU, EEC and pylon junction box.
     (a) Remove the access panel from the pylon to get access to the HCU:
       1 FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
413AL
       2 FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
423AL
     (b) Open the fan cowl-doors AMM 71-13-00-010-802.
   (2) At HCU pressure switch (102EG), make sure that the target is not missing and do a visual inspection of the target for bend, breakage or damage AMM 78-31-00-210-802.
     (a) If you find a bend, breakage or other damage, or if the target is missing:
       1 Replace HCU-T/R, ENG1 [4310EG1] or HCU-T/R, ENG2 [4310EG2] AMM 78-31-01-000-801 and AMM 78-31-01-400-801.
       2 Do the test given in Para. 3.
   (3) If you find no damage or if the fault continues:
     (a) Check for the correct engagement of connector (102EG_A) and HCU pressure switch (102EG):
       1 Repair as necessary.
       2 Do the test given in Para. 3.
   (4) If the check is OK or if the fault continues, use a PLIERS - JAWED, SOFT to disconnect connector (102EG-A) and do a visual inspection of the connector for bent pins, contamination or corrosion or other signs of damage.
     (a) If you find damage, replace the pylon harness:
       1 FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
AWM 783611
       2 FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
AWM 783612
     (b) Reconnect connector (102EG-A).
     (c) Do the test given in Para. 3.
   (5) If you find no damage or if that fault continues, disconnect connectors (102EG-A) and P1 from the EEC (4000KS) AWM 715135.
     (a) Do a continuity check (less than 5 ohms) between the pins of connectors P1 and (102EG-A) as follows:
  • Pin M and pin 2
  • Pin L and pin 5
  • Pin j and pin 3.
     (b) If there is no continuity:
  • Disconnect connector (P402) at pylon junction box.
     (c) Do a continuity check (less than 5 ohms) between the pins of connectors P1 and (P402) as follows:
  • Pin M and pin 14
  • Pin L and pin 13
  • Pin j and pin 28.
     (d) Do a check of each wire for wire-to-wire, short circuit and short to ground.
     (e) If you find a fault:
       1 Replace HARNESS-FAN, WF02 [4218KS] AMM 73-21-62-000-802 and AMM 73-21-62-400-802.
       2 Do the test given in Para. 3.
     (f) If there is continuity:
       1 Replace the pylon harness:
         a FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
AWM 783611
         b FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
AWM 783612
       2 Reconnect all connectors.
       3 Do the test given in Para. 3.
   (6) If there is continuity between connectors P1 and (102EG-A) or if fault continues, disconnect connector (102EG-A) and do a visual inspection of the HCU pressure switch (102EG) for bent pins, contamination or corrosion, or other signs of damage.
     (a) If you find damage, replace HCU PRESS SWITCH ENG 1A [102EG1] or HCU PRESS SWITCH ENG 2A [102EG2] AMM 78-31-21-000-801 and AMM 78-31-21-400-801.
     (b) Do the test given in Para. 3.
   (7) If you find no damage or if the fault continues, disconnect connector (102EG-A) and do a check for continuity of HCU pressure switch (102EG).
     (a) Make sure that the resistance is between 6.5 and 7.5 kohms between pins 2 and 5.
     (b) Make sure that the resistance is more than 100 kohms between pins 2 and 3.
     (c) If you find a fault, replace HCU PRESS SWITCH ENG 1A [102EG1] or HCU PRESS SWITCH ENG 2A [102EG2] AMM 78-31-21-000-801 and AMM 78-31-21-400-801.
     (d) Do the test given in Para. 3.
   (8) If you find no fault or if the fault continues, replace [4000KS] AMM 73-21-01-000-801 and AMM 73-21-01-400-801.
5. Close-up
Subtask 78-31-00-860-053-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
     (a) Close the fan cowl doors AMM 71-13-00-410-802.
     (b) Close the pylon access panel:
       1 FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
413AL
       2 FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
423AL