Indication of Reverser Fault Warning at Engine Shutdown/Master Lever Selection to OFF on Engine 2
TASK 78-31-00-810-868-A
Indication of Reverser Fault Warning at Engine Shutdown/Master Lever Selection to OFF on Engine 2
1. Possible Causes
Subtask 78-31-00-710-180-A ** ON A/C NOT FOR ALL
Subtask 78-31-00-810-127-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:38:05 UTC
Indication of Reverser Fault Warning at Engine Shutdown/Master Lever Selection to OFF on Engine 2
1. Possible Causes
- nuisance warning
Subtask 78-31-00-710-180-A ** ON A/C NOT FOR ALL
A. Test
(1) Not applicable.
3. Fault Isolation(1) Not applicable.
Subtask 78-31-00-810-127-A ** ON A/C NOT FOR ALL
A. If the ECAM warning ENG 2 REVERSER FAULT was reported at engine shutdown after master lever was selected to OFF with ECU PN 1820M36P07 or 1820M89P07 and no associated failure message:
Subtask 78-31-00-710-181-A ** ON A/C NOT FOR ALL - no maintenance action is required. The nuisance warning is spurious.
NOTE: The ECU PN can be checked on MCDU screen (Access Engine 2 SYSTEM REPORT TEST, FADEC LRU identification screen).
B. No additional maintenance action is required if the fault is not confirmed.
(1) Repeat the fault isolation procedure if the fault continues.
(1) Repeat the fault isolation procedure if the fault continues.