Failure of the T/R Hydraulic Isolation Valve in the Open Position on the Engine 1
TASK 78-31-00-810-861-A
Failure of the T/R Hydraulic Isolation Valve in the Open Position on the Engine 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 78-31-00-710-158-B ** ON A/C NOT FOR ALL
Subtask 78-31-00-865-052-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:38:04 UTC
Failure of the T/R Hydraulic Isolation Valve in the Open Position on the Engine 1
1. Possible Causes
VALVE-THRUST REVERSER HYDRAULIC ISOLATION, ENG1 (50EG1) STATIC RELAY-THRUST REVERSER LOCKING CTL, ENG1 (3EG1) RELAY-THRUST REVERSER LOCKING POWER, ENG1 (2EG1) - SEC-1 [1CE1]
- SEC-2 [1CE2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 78-31-00-710-040 | Operational Test of the Thrust Reverser System |
| AMM 78-31-00-710-042 | Operational Test of the Thrust Reverser System |
| ASM 783701 | |
| AMM 78-37-51-000-001 | Removal of the Thrust Reverser Hydraulic Isolation Valve |
| AMM 78-37-51-000-002 | Removal of the Thrust Reverser Hydraulic Isolation Valve |
| AMM 78-37-51-400-001 | Installation of the Thrust Reverser Hydraulic Isolation Valve |
| AMM 78-37-51-400-002 | Installation of the Thrust Reverser Hydraulic Isolation Valve |
Subtask 78-31-00-710-158-B ** ON A/C NOT FOR ALL
A. Test
(1) Open, safety and tag the circuit breaker 1EG1 and do the operational test of the thrust reverser system (1A and 1B) AMM 78-31-00-710-040.
Subtask 78-31-00-710-158-C ** ON A/C NOT FOR ALL (1) Open, safety and tag the circuit breaker 1EG1 and do the operational test of the thrust reverser system (1A and 1B) AMM 78-31-00-710-040.
A. Test
(1) Open, safety and tag the circuit breaker 1EG1 and do the operational test of the thrust reverser system (1A and 1B) AMM 78-31-00-710-042.
4. Fault Isolation(1) Open, safety and tag the circuit breaker 1EG1 and do the operational test of the thrust reverser system (1A and 1B) AMM 78-31-00-710-042.
Subtask 78-31-00-865-052-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 78-31-00-810-112-C ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENG1/REV/LOCK | 1EG1 | N44 |
B. The fault message is generated if the ECU detects a pressurization of the thrust reverser HCU during the thrust reverser isolation valve monitoring test after the engine start. The message indicates that the thrust reverser isolation valve has failed in the open position or is leaking internally.
(1) If the thrust reverser blocker doors deployed during the test:
Subtask 78-31-00-810-112-D ** ON A/C NOT FOR ALL (1) If the thrust reverser blocker doors deployed during the test:
- replace the
VALVE-THRUST REVERSER HYDRAULIC ISOLATION, ENG1 (50EG1) AMM 78-37-51-000-001 and AMM 78-37-51-400-001.
- look for the cause of abnormal permanent electrical supply of the thrust reverser isolation valve or undue fault annunciation as follows ASM 783701,
- replace the
STATIC RELAY-THRUST REVERSER LOCKING CTL, ENG1 (3EG1) .
- replace the
RELAY-THRUST REVERSER LOCKING POWER, ENG1 (2EG1) .
- remove the static relay (3EG1) from its base on shelf 120VU and do a check for permanent ground at pin A/1.
- do a check for short to ground between the SEC1 (1CE1), the SEC2 (1CE2) and the static relay (3EG1).
- repair as required.
- do the trouble shooting of the SEC1 (1CE1) and the SEC2 (1CE2) for abnormal ground at pin AB/15E on the SEC1 (1CE1) and at pin AB/15E on the SEC2 (1CE2) ASM 783701,
- look for any FCDC or radio altimeter failure (in Post Flight Report (PFR)) causing SEC output malfunction (TSM chapter 27).
. If no external failure to the SECs is found: - replace successively the SEC-1 [1CE1] then the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
B. The fault message is generated if the ECU detects a pressurization of the thrust reverser HCU during the thrust reverser isolation valve monitoring test after the engine start. The message indicates that the thrust reverser isolation valve has failed in the open position or is leaking internally.
Subtask 78-31-00-865-054-A ** ON A/C NOT FOR ALL NOTE: If the failure message TR ISOL VALVE, HCU was set with failure message TR PR SW, J5/J6, ECU, do the trouble shooting for failure message TR PR SW, J5/J6, ECU separately.
(1) If the thrust reverser blocker doors deployed during the test: - replace the
VALVE-THRUST REVERSER HYDRAULIC ISOLATION, ENG1 (50EG1) AMM 78-37-51-000-002 and AMM 78-37-51-400-002.
- look for the cause of abnormal permanent electrical supply of the thrust reverser isolation valve or undue fault annunciation as follows ASM 783701,
- replace the
STATIC RELAY-THRUST REVERSER LOCKING CTL, ENG1 (3EG1) .
- replace the
RELAY-THRUST REVERSER LOCKING POWER, ENG1 (2EG1) .
- remove the static relay (3EG1) from its base on shelf 120VU and do a check for permanent ground at pin A/1.
- do a check for short to ground between the SEC1 (1CE1), the SEC2 (1CE2) and the static relay (3EG1).
- repair as required.
- do the trouble shooting of the SEC1 (1CE1) and the SEC2 (1CE2) for abnormal ground at pin AB/15E on the SEC1 (1CE1) and at pin AB/15E on the SEC2 (1CE2) ASM 783701,
- look for any FCDC or radio altimeter failure (in Post Flight Report (PFR)) causing SEC output malfunction (TSM chapter 27).
. If no external failure to the SECs is found: - replace successively the SEC-1 [1CE1] then the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 78-31-00-710-170-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENG1/REV/LOCK | 1EG1 | N44 |
D. Check that the warning and failure message do not duplicate at next engine start.