Stow Time Too Long on Engine 1 Thrust Reverser
TASK 78-31-00-810-847-A
Stow Time Too Long on Engine 1 Thrust Reverser
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 78-31-00-710-140-A ** ON A/C NOT FOR ALL
Subtask 78-31-00-810-096-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:38:02 UTC
Stow Time Too Long on Engine 1 Thrust Reverser
1. Possible Causes
- shut-off valve filter
- HCU filter
CHECK VALVE-ENG 1 THR REV, G - HCU return line
HCU-THRUST REV (4101KS) - ECU [4000KS]
- ACTUATOR-BLOCKER DOOR, UPPER R [3001KM1]
- ACTUATOR-BLOCKER DOOR, LOWER R [3001KM2]
- ACTUATOR-BLOCKER DOOR, LOWER L [3001KM3]
- ACTUATOR-BLOCKER DOOR, UPPER L [3001KM4]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-11-35-000-001 | Removal of the Engine 1 Thrust Reverser Check Valve |
| AMM 29-11-35-400-001 | Installation of the Engine 1 Thrust Reverser Check Valve |
| AMM 73-21-60-000-001 | Removal of the Electronic Control Unit (ECU) |
| AMM 73-21-60-400-001 | Installation of the Electronic Control Unit (ECU) |
| AMM 78-31-00-710-040 | Operational Test of the Thrust Reverser System |
| AMM 78-31-00-710-042 | Operational Test of the Thrust Reverser System |
| AMM 78-31-41-000-001 | Removal of the Blocker Door Hydraulic Actuator |
| AMM 78-31-41-000-040 | Removal of the Blocker Door Hydraulic Actuators |
| AMM 78-31-41-210-003 | Detailed Visual Inspection of the Door Actuator |
| AMM 78-31-41-210-040 | Detailed Visual Inspection of the Blocker Door Actuator |
| AMM 78-31-41-400-001 | Installation of the Blocker Door Hydraulic Actuator |
| AMM 78-31-41-400-040 | Installation of the Blocker Door Hydraulic Actuators |
| AMM 78-31-51-000-040 | Removal of the Hydraulic Control Unit |
| AMM 78-31-51-000-042 | Removal of the Hydraulic Control Unit |
| AMM 78-31-51-400-040 | Installation of the Hydraulic Control Unit |
| AMM 78-31-51-400-042 | Installation of the Hydraulic Control Unit |
| AMM 78-31-51-920-001 | Replacement of the Hydraulic Control Unit Filter |
| AMM 78-31-51-920-040 | Replacement of the Hydraulic Control Unit Filter |
| AMM 78-32-41-860-001 | Manual Deployment of the Blocker Door |
| AMM 78-37-51-600-001 | Replacement of the Thrust Reverser Hydraulic Isolation Valve Filter |
| AMM 78-37-51-600-002 | Replacement of the Thrust Reverser Hydraulic Isolation Valve Filter |
Subtask 78-31-00-710-140-A ** ON A/C NOT FOR ALL
A. Test
Subtask 78-31-00-710-140-B ** ON A/C NOT FOR ALL CAUTION:
STAY AWAY FROM THE TRAVEL RANGE OF THE BLOCKER DOORS DURING THE TEST.
(1) Do an operational test of the thrust reverser system for the FADEC 1A AMM 78-31-00-710-042. Visually monitor the blocker doors operation during the test. A. Test
4. Fault IsolationCAUTION:
STAY AWAY FROM THE TRAVEL RANGE OF THE BLOCKER DOORS DURING THE TEST.
(1) Do an operational test of the thrust reverser system for the FADEC 1A AMM 78-31-00-710-040. Visually monitor the blocker doors operation during the test. Subtask 78-31-00-810-096-B ** ON A/C NOT FOR ALL
A. The fault message HCU is generated if the thrust reverser stow time is greater than 8 seconds between the setting of the throttle from reverse to forward idle and the locking of the reverser blocker doors.
(1) If all blocker doors stow simultaneously but slowly during the test:
Subtask 78-31-00-810-096-F ** ON A/C NOT FOR ALL (1) If all blocker doors stow simultaneously but slowly during the test:
- do a check of the filter clogging pop out indicator of the reverser shut-off valve filter.
- replace the shut-off valve filter AMM 78-37-51-600-002.
- do a check of the HCU filter clogging pop out indicator.
- replace the HCU filter AMM 78-31-51-920-001.
- remove the hydraulic return line between the HCU and the check valve (3010KM1) at the pylon connection,
- do an inspection for blockage or damage.
- clean or replace the
CHECK VALVE-ENG 1 THR REV, G AMM 29-11-35-000-001 and AMM 29-11-35-400-001 or HCU return line .
- replace the
HCU-THRUST REV (4101KS) AMM 78-31-51-000-042 and AMM 78-31-51-400-042.
- replace the ECU [4000KS] AMM 73-21-60-000-001 and AMM 73-21-60-400-001.
- do a manual deployment of the thrust reverser blocker doors AMM 78-32-41-860-001,
- with the blocker doors in the deployed position, do a visual inspection of the structure and hydraulic lines AMM 78-31-41-210-003.
- replace the damaged parts.
- replace the defective:
. ACTUATOR-BLOCKER DOOR, UPPER R [3001KM1] or/and
. ACTUATOR-BLOCKER DOOR, LOWER R [3001KM2] or/and
. ACTUATOR-BLOCKER DOOR, LOWER L [3001KM3] or/and
. ACTUATOR-BLOCKER DOOR, UPPER L [3001KM4] AMM 78-31-41-000-001 and AMM 78-31-41-400-001.
- replace the
HCU-THRUST REV (4101KS) AMM 78-31-51-000-042 and AMM 78-31-51-400-042.
A. The fault message HCU is generated if the thrust reverser stow time is greater than 8 seconds between the setting of the throttle from reverse to forward idle and the locking of the reverser blocker doors.
(1) If all blocker doors stow simultaneously but slowly during the test:
Subtask 78-31-00-710-141-A ** ON A/C NOT FOR ALL (1) If all blocker doors stow simultaneously but slowly during the test:
- do a check of the filter clogging pop out indicator of the reverser shut-off valve filter.
- replace the shut-off valve filter AMM 78-37-51-600-001.
- do a check of the HCU filter clogging pop out indicator.
- replace the HCU filter AMM 78-31-51-920-040.
- remove the hydraulic return line between the HCU and the check valve (3010KM1) at the pylon connection,
- do an inspection for blockage or damage.
- clean or replace the
CHECK VALVE-ENG 1 THR REV, G AMM 29-11-35-000-001 and AMM 29-11-35-400-001 or HCU return line .
- replace the
HCU-THRUST REV (4101KS) AMM 78-31-51-000-040 and AMM 78-31-51-400-040.
- replace the ECU [4000KS] AMM 73-21-60-000-001 and AMM 73-21-60-400-001.
- do a manual deployment of the thrust reverser blocker doors AMM 78-32-41-860-001,
- with the blocker doors in the deployed position, do a visual inspection of the structure and hydraulic lines AMM 78-31-41-210-040.
- replace the damaged parts.
- replace the defective:
. ACTUATOR-BLOCKER DOOR, UPPER R [3001KM1] or/and
. ACTUATOR-BLOCKER DOOR, LOWER R [3001KM2] or/and
. ACTUATOR-BLOCKER DOOR, LOWER L [3001KM3] or/and
. ACTUATOR-BLOCKER DOOR, UPPER L [3001KM4] AMM 78-31-41-000-040 and AMM 78-31-41-400-040.
- replace the
HCU-THRUST REV (4101KS) AMM 78-31-51-000-040 and AMM 78-31-51-400-040.
B. Do the test given in Para. 3.A.
(1) No additional maintenance action is required if the fault is not confirmed.
(2) Repeat the fault isolation procedure if the fault continues.
(1) No additional maintenance action is required if the fault is not confirmed.
(2) Repeat the fault isolation procedure if the fault continues.