Loss of the Signal of the Thrust-Reverser Blocker-Door Deploy/Stow Stwitches through the Channel A on Engine 2


TASK 78-31-00-810-813-A
Loss of the Signal of the Thrust-Reverser Blocker-Door Deploy/Stow Stwitches through the Channel A on Engine 2


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 78-31-00-810-840-A
Thrust-Reverser Blocker-Door Stow-Switches Feedback Disagree on Engine 2
TSM TASK 78-31-00-810-844-A
Thrust-Reverser Blocker-Door Deploy-Switches Feedback Disagree on Engine 2
AMM 78-31-00-710-040
Operational Test of the Thrust Reverser System
3. Fault Confirmation
Subtask 78-31-00-710-074-A ** ON A/C NOT FOR ALL
A. Do the operational test of the thrust reverser system (2A) AMM 78-31-00-710-040.
4. Fault Isolation
Subtask 78-31-00-810-062-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DEPL/STOW SW, J5:
NOTE: A fault has been detected which cannot be isolated to the thrust-reverser blocker-door deploy and/or stow-switch circuits.