W DOC AIRBUS | TSM A320F

Failure of the Thrust Reverser HCU on the Engine 1, Channel A



1. Possible Causes
· HCU-THRUST REV (4101KS)
· wiring from the EEC (4000KS) to the thrust reverser HCU (4101KS)
· EEC ( 4000KS )
2 Job Set-up Information
A. Referenced Information
REFERENCE DESIGNATION
Ref. AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power
Ref. AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External
Power
Ref. AMM 31-60-00-860-002 EIS Stop Procedure
Ref. AMM 71-13-00-410-010 Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
Ref. AMM 73-22-34-000-010 Removal of the Electronic Engine Control (EEC)
Ref. AMM 73-22-34-400-010 Installation of the Electronic Engine Control (EEC)
Ref. ASM 73-25-16
Ref. AMM 78-31-00-710-041 Operational Test of the Thrust Reverser System with the CFDS
Ref. AMM 78-31-51-000-010 Removal of the Thrust Reverser Hydraulic Control Unit
Ref. AMM 78-31-51-400-010 Installation of the Thrust Reverser Hydraulic Control Unit
Thrust Reverser Hydraulic Control Unit (Engine 1, Channel A) SHEET 1
Figure 78(IAE)-30-00-991-02300-A / SHEET 1/1 - Thrust Reverser Hydraulic Control Unit (Engine 1,
Channel A) not printed, as per printing preferences
3. Fault Confirmation
Subtask 78-30-00-860-124-A
A. Job Set-Up
(1) Energize the aircraft electrical circuits
Ref. AMM 24-41-00-861-002 .
(2) On the panel 50VU, release the ENG/FADEC GND PWR/1 pushbutton switch.
Subtask 78-30-00-710-232-A
B. Test
(1) On the panel 50VU, push the ENG/FADEC GND PWR/1 pushbutton switch and release it again.
NOTE: This action resets the FADEC memory.
(2) Do the operational test of the thrust reverser system with the CFDS (FADEC 1A) Ref.
AMM 78-31-00-710-041 .
4. Fault Isolation
(Ref. Fig. Thrust Reverser Hydraulic Control Unit (Engine 1, Channel A) SHEET 1)
Subtask 78-30-00-810-158-A
A. If the test gives the maintenance message CHA HYD CONT UNIT/HC/EEC1:
· replace the HCU-THRUST REV (4101KS) Ref. AMM 78-31-51-000-010 and Ref.
AMM 78-31-51-400-010 .
(1) If the fault continues:
· read the fault code shown on the FLIGHT DATA and GROUND DATA of the FADEC 1A menu on
the MCDU (Ref. 70-00-00 Page Block 301 Task Supporting Data).
· record the fault code.
(2) If the FADEC 1A menu gives the fault code ARMWAF:
· do a check and repair the wiring from the EEC (4000KS) to the thrust reverser HCU (4101KS) :
. pins J3/D, C to pins A/2, 3 Ref. ASM 73-25-16.
(3) If the fault continues:
· replace the EEC ( 4000KS ) Ref. AMM 73-22-34-000-010 and Ref. AMM 73-22-34-400-010 .
Subtask 78-30-00-710-233-A
B. Do the test given in Para. 3.
5. Close-up
Subtask 78-30-00-860-125-A
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
Ref. AMM 31-60-00-860-002 .
(2) On the panel 50VU, push the ENG/FADEC GND PWR/1 pushbutton switch.
(3) De-energize the aircraft electrical circuits
Ref. AMM 24-41-00-862-002 .
(4) Make sure that the fan cowls 437AL and 438AR are closed Ref. AMM 71-13-00-410-010 . [Rev.6 from Feb 2017] 2026.04.04 04:38:10 UTC