W DOC AIRBUS | TSM A320F

Failure of the TRF Vibration Sensor on Engine 2


TASK 77-30-00-810-812-A
Failure of the TRF Vibration Sensor on Engine 2


1. Possible Causes
  • wiring from the EVMU (2EV) to the TRF vibration sensor (4003EV)
  • SENSOR-TRF VIB [4003EV]
  • EVMU [2EV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 77-31-30-000-001
Removal of the Turbine Rear Frame Vibration Sensor
AMM 77-31-30-000-002
Removal of the Turbine Rear Frame Vibration Sensor
AMM 77-31-30-400-001
Installation of the Turbine Rear Frame Vibration Sensor
AMM 77-31-30-400-002
Installation of the Turbine Rear Frame Vibration Sensor
ASM 773202
AMM 77-32-34-000-040
Removal of the Monitoring Unit Engine Vibration (EVMU)
AMM 77-32-34-000-042
Removal of the Engine Vibration Monitoring Unit (EVMU)
AMM 77-32-34-400-040
Installation of the Vibration Monitoring Unit (EVMU)
AMM 77-32-34-400-042
Installation of the Engine Vibration Monitoring Unit (EVMU)
AMM 77-32-34-710-040
Operational Check of EVMU through CFDS for Advisory Indication on ECAM
AMM 77-32-34-860-041
Change the configuration of the Accelerometer
AMM 77-32-34-869-041
Change the configuration of the Accelerometer
3. Fault Confirmation
Subtask 77-30-00-710-069-A ** ON A/C NOT FOR ALL
A. Test
Do the operational test of the Engine Vibration Monitoring Unit (EVMU) through the Centralized Fault Display System (CFDS) AMM 77-32-34-710-040.
4. Fault Isolation
Subtask 77-30-00-810-060-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ENG 2 SECOND ACCEL:
  • do a check of the wiring from the EVMU (2EV) to the TRF vibration sensor (4003EV) pins AB/1C, 2D to pins AA/2, 3 ASM 773202.
   (1) If there is no continuity:
  • repair the above wiring.
   (2) If there is continuity:
   (3) If the fault continues:
Subtask 77-30-00-810-060-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ENG 2 SECOND ACCEL:
  • do a check of the wiring from the EVMU (2EV) to the TRF vibration sensor (4003EV) pins AB/1C, 2D to pins AA/2, 3 ASM 773202.
   (1) If there is no continuity:
  • repair the above wiring.
   (2) If there is continuity:
   (3) If the fault continues:
Subtask 77-30-00-710-070-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:37:47 UTC