N1 Sensor Electrical Failure on Channel A and B
TASK 77-11-00-810-855-A
N1 Sensor Electrical Failure on Channel A and B
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 77-11-00-710-111-A ** ON A/C NOT FOR ALL
Subtask 77-11-00-810-178-A ** ON A/C NOT FOR ALL
Subtask 77-11-00-860-096-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:37:55 UTC
N1 Sensor Electrical Failure on Channel A and B
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 77-11-00-810-808-A | N1 Sensor Electrical Failure Channel B |
| TSM TASK 77-11-00-810-809-A | N1 Sensor Electrical Failure Channel A |
Subtask 77-11-00-710-111-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault IsolationSubtask 77-11-00-810-178-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
(1) Do the troubleshooting procedure (Ref. TSM TASK 77-11-00-810-809).
(2) Do the troubleshooting procedure (Ref. TSM TASK 77-11-00-810-808).
5. Close-up(1) Do the troubleshooting procedure (Ref. TSM TASK 77-11-00-810-809).
(2) Do the troubleshooting procedure (Ref. TSM TASK 77-11-00-810-808).
Subtask 77-11-00-860-096-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(1) Make sure that the work area is clean and clear of tools and other items.