W DOC AIRBUS | TSM A320F

Loss of the Feedback Signal of the N2 Speed Sensor through the Channel A on Engine 2


TASK 77-10-00-810-832-A
Loss of the Feedback Signal of the N2 Speed Sensor through the Channel A on Engine 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 73-21-50-000-006
Removal of J7 Harness
AMM 73-21-50-400-006
Installation of the J7 Harness
AMM 73-21-60-000-001
Removal of the Electronic Control Unit (ECU)
AMM 73-21-60-400-001
Installation of the Electronic Control Unit (ECU)
ASM 732513
AMM 73-29-00-710-040
Operational Test of the FADEC on the ground (with Engine Motoring)
AMM 77-11-20-000-001
Removal of the N2 Speed Sensor
AMM 77-11-20-400-001
Installation of the N2 Speed Sensor
3. Fault Confirmation
Subtask 77-10-00-710-112-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the FADEC 2A on the ground (with engine non motoring) AMM 73-29-00-710-040.
   (2) Read the CLASS 3 FAULT of the FADEC (2A) on the MCDU and make a record of the class 3 maintenance message.
4. Fault Isolation
Subtask 77-10-00-810-084-A ** ON A/C NOT FOR ALL
A. If the test of the channel A gives the maintenance message N2 SNSR, J7, ECU ENG2A:
  • Do a check for open or short to ground of the harness J7 between the ECU (4000KS) and the N2 speed sensor ASM 732513.
   (1) If the wiring is not correct:
  • Repair the above wiring.
   (2) If the wiring is correct:
  • Disconnect the harness J7 from the ECU (4000KS) and do a resistance check of the cable between:
    . Pins 2 and 11 (40 to 80 ohms)
    . Pins 2 and 3 (> 10 megohms)
    . Pin 2 and the ground (> 10 megohms).
     (a) If the resistance values are in the specified limits:
     (b) If the resistance values are out of the specified limits:
  • Disconnect the harness J7 from the N2 speed sensor and do a resistance check of the sensor between:
    . Pins 1 and 2 (40 to 80 ohms)
    . Pins 1 and 3 (> 10 megohms)
    . Pin 1 and the ground (> 10 megohms).
       1 If the resistance values are in the specified limits:
       2 If the resistance values are out of the specified limits:
Subtask 77-10-00-710-113-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:37:40 UTC