W DOC AIRBUS | TSM A320F

Loss of the Feedback Signal of the N2 Speed Sensor - Engine 1 - Channel B


TASK 77-10-00-810-822-A
Loss of the Feedback Signal of the N2 Speed Sensor - Engine 1 - Channel B


1. Possible Causes
  • SENSOR-N2 ROTATIONAL SPD [4001EV]
  • ECU [4000KS]
  • J8 harness
  • HJ8 harness
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
BRUSH - BRISTLED
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.CP2011)
stoddard solvent
 C. Referenced Information
REFERENCE
DESIGNATION
AMM 73-21-50-000-007
Removal of J8 Harness
AMM 73-21-50-000-041
Removal of the HJ8 Harness for SAC Engines
AMM 73-21-50-210-001
Visual Inspection of the Wiring Harness
AMM 73-21-50-210-002
Visual Inspection of the Wiring Harnesses
AMM 73-21-50-400-007
Installation of the J8 Harness
AMM 73-21-50-400-041
Installation of the HJ8 Harness for SAC Engines
AMM 73-21-60-000-001
Removal of the Electronic Control Unit (ECU)
AMM 73-21-60-400-001
Installation of the Electronic Control Unit (ECU)
AMM 73-29-00-710-040
Operational Test of the FADEC on the ground (with Engine Motoring)
AMM 77-11-20-000-001
Removal of the N2 Speed Sensor
AMM 77-11-20-000-002
Removal of the N2 Speed Sensor .
AMM 77-11-20-400-001
Installation of the N2 Speed Sensor
AMM 77-11-20-400-002
Installation of the N2 Speed Sensor .
3. Fault Confirmation
Subtask 77-10-00-710-092-A ** ON A/C NOT FOR ALL
A. Do the operational test of the FADEC 1B on the ground (with engine non motoring) AMM 73-29-00-710-040.
4. Fault Isolation
Subtask 77-10-00-810-071-A ** ON A/C NOT FOR ALL
A. The failure message is generated if channel B input from the N2 sensor is invalid or out of range.
   (1) If the failure message N2 SENS, J8, ECU is not confirmed:
     (a) No maintenance action is required.
   (2) If the failure message N2 SENS, J8, ECU is not confirmed but is repetitive:
  • disconnect J8 harness from the N2 sensor (N2-B connector).
     (a) Visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-001.
       1 If damage is found:
  • repair or replace as required.
       2 If no damage is found:
  • do a cleaning of the connector and receptacle using a BRUSH - BRISTLED with stoddard solvent (Material No.CP2011) AMM 73-21-50-210-001.
     (b) If the failure continues during the subsequent flights:
     (c) If the failure continues during the subsequent flights:
     (d) If the failure continues during the subsequent flights:
   (3) If the failure message N2 SENS, J8, ECU is confirmed:
  • disconnect the J8 harness from the N2 sensor (N2-B connector).
     (a) Visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-001.
       1 If damage is found:
  • repair or replace as required.
       2 If no damage is found:
  • do the electrical resistance test through the N2 sensor (4001EV) (channel B) between:
    . pins 1 and 2 (40 to 80 ohms)
    . pins 1 and 3 (>10 megohms)
    . pin 1 and the ground (>10 megohms).
         a If the resistance values are out of the specified limits:
         b If the resistance values are in the specified limits:
  • connect the J8 harness to the N2 sensor.
     (b) Disconnect the J8 harness from the ECU (4000KS) and visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-001.
       1 If damage is found:
  • repair or replace as required.
       2 If no damage is found:
  • do the electrical resistance test through the J8 harness between:
    . pins 2 and 11 (40 to 80 ohms)
    . pins 2 and 3 (>10 megohms)
    . pin 2 and the ground (>10 megohms).
         a If the resistance values are in the specified limits:
         b If the resistance values are out of the specified limits:
Subtask 77-10-00-810-071-B ** ON A/C NOT FOR ALL
A. The failure message is generated if channel B input from the N2 sensor is invalid or out of range.
   (1) If the failure message N2 SNSR, J8, ECU is not confirmed:
     (a) No maintenance action is required.
   (2) If the failure message N2 SNSR, J8, ECU is not confirmed but is repetitive:
  • disconnect J8 harness from the N2 sensor (N2-B connector).
     (a) Visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-001.
       1 If damage is found:
  • repair or replace as required.
       2 If no damage is found:
  • do a cleaning of the connector and receptacle using a BRUSH - BRISTLED with stoddard solvent (Material No.CP2011) AMM 73-21-50-210-001.
     (b) If the failure continues during the subsequent flights:
     (c) If the failure continues during the subsequent flights:
     (d) If the failure continues during the subsequent flights:
   (3) If the failure message N2 SNSR, J8, ECU is confirmed:
  • disconnect the J8 harness from the N2 sensor (N2-B connector).
     (a) Visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-001.
       1 If damage is found:
  • repair or replace as required.
       2 If no damage is found:
  • do the electrical resistance test through the N2 sensor (4001EV) (channel B) between:
    . pins 1 and 2 (40 to 80 ohms)
    . pins 1 and 3 (>10 megohms)
    . pin 1 and the ground (>10 megohms).
         a If the resistance values are out of the specified limits:
         b If the resistance values are in the specified limits:
  • connect the J8 harness to the N2 sensor.
     (b) Disconnect the J8 harness from the ECU (4000KS) and visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-001.
       1 If damage is found:
  • repair or replace as required.
       2 If no damage is found:
  • do the electrical resistance test through the J8 harness between:
    . pins 2 and 11 (40 to 80 ohms)
    . pins 2 and 3 (>10 megohms)
    . pin 2 and the ground (>10 megohms).
         a If the resistance values are in the specified limits:
         b If the resistance values are out of the specified limits:
Subtask 77-10-00-810-071-C ** ON A/C NOT FOR ALL
A. The failure message is generated if channel B input from the N2 sensor is invalid or out of range.
   (1) If the failure message N2 SNSR, J8, ECU is not confirmed:
     (a) No maintenance action is required.
   (2) If the failure message N2 SNSR, J8, ECU is not confirmed but is repetitive:
  • disconnect HJ8 harness from the N2 sensor (N2-B connector).
     (a) Visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-002.
       1 If damage is found:
  • repair or replace as required.
       2 If no damage is found:
  • do a cleaning of the connector and receptacle using a BRUSH - BRISTLED with stoddard solvent (Material No.CP2011) AMM 73-21-50-210-002.
     (b) If the failure continues during the subsequent flights:
     (c) If the failure continues during the subsequent flights:
     (d) If the failure continues during the subsequent flights:
   (3) If the failure message N2 SNSR, J8, ECU is confirmed:
  • disconnect the HJ8 harness from the N2 sensor (N2-B connector).
     (a) Visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-002.
       1 If damage is found:
  • repair or replace as required.
       2 If no damage is found:
  • do the electrical resistance test through the N2 sensor (4001EV) (channel B) between:
    . pins 1 and 2 (40 to 80 ohms)
    . pins 1 and 3 (>10 megohms)
    . pin 1 and the ground (>10 megohms).
         a If the resistance values are out of the specified limits:
         b If the resistance values are in the specified limits:
  • connect the HJ8 harness to the N2 sensor.
     (b) Disconnect the HJ8 harness from the ECU (4000KS) and visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-002.
       1 If damage is found:
  • repair or replace as required.
       2 If no damage is found:
  • do the electrical resistance test through the HJ8 harness between:
    . pins 2 and 11 (40 to 80 ohms)
    . pins 2 and 3 (>10 megohms)
    . pin 2 and the ground (>10 megohms).
         a If the resistance values are in the specified limits:
         b If the resistance values are out of the specified limits:
Subtask 77-10-00-710-093-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
   (1) No additional maintenance action is required if the fault is not confirmed.
   (2) Repeat the fault isolation procedure if the fault continues.
[Rev.8 from Aug 2018] 2026.04.04 04:37:38 UTC