W DOC AIRBUS | TSM A320F

TO/GA Inputs Invalid on Engine 2


TASK 77-00-00-810-911-A
TO/GA Inputs Invalid on Engine 2


1. Possible Causes
  • P0 port on the ECU
  • PS12 sense line
  • LGCIU-2 [5GA2]
  • EIU-2 [1KS2]
  • ECU [4000KS]
  • ADIRU 1
  • ADIRU 2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 73-25-00-810-917-A
Loss of Weight on Wheels Signal on the System 2
AMM 73-21-60-000-001
Removal of the Electronic Control Unit (ECU)
AMM 73-21-60-400-001
Installation of the Electronic Control Unit (ECU)
3. Fault Confirmation
Subtask 77-00-00-710-275-A ** ON A/C NOT FOR ALL
A. Test
   (1) The fault cannot be confirmed by the ground test.
4. Fault Isolation
Subtask 77-00-00-810-195-A ** ON A/C NOT FOR ALL
A. This failure message will be set if the ECU cannot determine the take-off or go around state due to disagreement on flight/ground input signals.
   (1) If the failure message ADC1+ADC2+LGCIU2 is displayed:
  • look at the Post Flight Report or the Last Leg Report for failure message EIU, LGCIU (WOW).
     (a) If there is this message:
       1 The fault may be caused by:
  • a blockage of the P0 port on the ECU ,
  • a blockage or leakage on the PS12 sense line ,
  • an LGCIU-2 [5GA2] system failure,
  • an EIU-2 [1KS2] or an ECU [4000KS] internal failure.
     (b) If there is not this message:
  • look for failure message relative to ADIRU 1 or ADIRU 2 or pitot or static probes.
       1 If there is a message:
  • do the applicable trouble shooting procedure.
       2 If there is no message:
Subtask 77-00-00-710-276-A ** ON A/C NOT FOR ALL
B. No additional maintenance action is required if the fault is not confirmed.
   (1) Repeat the fault isolation procedure if the fault continues.
[Rev.8 from Aug 2018] 2026.04.04 04:37:35 UTC