W DOC AIRBUS | TSM A320F

Loss of the Channels A and B of the FADEC on Engine 1


TASK 77-00-00-810-882-A
Loss of the Channels A and B of the FADEC on Engine 1


1. Possible Causes
  • ECU [4000KS]
  • harnesses J1 and J2
  • EIU-1 [1KS1]
  • aircraft wirings
  • C/B-ENGINE/1/FADEC A/AND EIU 1 [2KS1]
  • C/B-ENGINE/ENG1/FADEC B/AND EIU 1 [4KS1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 71-00-00-710-006
Minimum Idle Check
AMM 73-21-60-000-001
Removal of the Electronic Control Unit (ECU)
AMM 73-21-60-400-001
Installation of the Electronic Control Unit (ECU)
ASM 732505
ASM 732508
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
AMM 73-29-00-710-040
Operational Test of the FADEC on the ground (with Engine Motoring)
3. Fault Confirmation
Subtask 77-00-00-710-197-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the FADEC 1A and 1B on the ground (with engine motoring) AMM 73-29-00-710-040.
4. Fault Isolation
Subtask 77-00-00-865-061-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
Subtask 77-00-00-810-152-A ** ON A/C NOT FOR ALL
B. If the fault symptom is identified by the upper ECAM warning ENG1 FADEC FAULT and the test of the FADEC 1A and 1B gives no manitenance message:
  • disconnect the connectors J1 and J2 from the ECU (4000KS) and do a check for 28VDC at pins J1 and J2 /13 with the FADEC GND PWR pushbutton switch released (the ON legend is on).
   (1) If there is 28VDC:
   (2) If there is no 28VDC:
  • do a check for 28VDC at EIU 1 (1KS1) pins AC/9, 11 ASM 732505.
     (a) If there is 28VDC:
  • do a check for open or short to ground at the harnesses J1 and J2 between the EIU 1 (1KS1) and the ECU (4000KS), pin AC/7 to pin J1/13 and pin AC/2 to pin J2/13. Replace the harness J1 or J2 if necessary.
       1 If the fault continues:
  • make sure that there is no ground signal at EIU 1 (1KS1) pin AA/5B ASM 732508.
       2 If the fault continues:
     (b) If there is no 28VDC:
  • do a check for open or short to ground at the aircraft wirings between the circuit breakers (2KS1), (4KS1) and EIU 1 (1KS1) pin AC/9, 11.
       1 If there is a short to ground:
  • repair the defective wiring(s).
       2 If there is no short to ground:
  • replace the defective C/B-ENGINE/1/FADEC A/AND EIU 1 [2KS1] or the C/B-ENGINE/ENG1/FADEC B/AND EIU 1 [4KS1] .
     (c) Make sure that 28VDC supplies the BAT and ESS buses ASM 732505.
     (d) Check the wiring 568 on the pin 3B at 1KS1:
  • Repair the above wiring.
Subtask 77-00-00-710-198-A ** ON A/C NOT FOR ALL
C. Do a minimum idle check AMM 71-00-00-710-006.
[Rev.8 from Aug 2018] 2026.04.04 04:37:35 UTC