Disagree between the EGT Indication and the ECU Output on Engine 1
TASK 77-00-00-810-823-A
Disagree between the EGT Indication and the ECU Output on Engine 1
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Fault Confirmation
Subtask 77-00-00-710-074-A ** ON A/C NOT FOR ALL
Subtask 77-00-00-810-062-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:37:31 UTC
Disagree between the EGT Indication and the ECU Output on Engine 1
1. Possible Causes
- EGT thermocouple
- CJ13 harness
- CJ13 and HJ13 harnesses
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | BRUSH - BRISTLED |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.CP2011) | stoddard solvent |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 73-21-50-210-001 | Visual Inspection of the Wiring Harness |
| AMM 73-21-50-210-002 | Visual Inspection of the Wiring Harnesses |
| AMM 77-21-10-000-001 | Removal of the Upper Extension Lead |
| AMM 77-21-10-000-002 | Removal of the Main Junction Box |
| AMM 77-21-10-000-008 | Removal of the Upper Extension Lead |
| AMM 77-21-10-000-025 | Removal of the Main Junction Box |
| AMM 77-21-10-400-001 | Installation of the Upper Extension Lead |
| AMM 77-21-10-400-002 | Installation of the Main Junction Box |
| AMM 77-21-10-400-008 | Installation of the Upper Extension Lead |
| AMM 77-21-10-400-025 | Installation of the Main Junction Box |
Subtask 77-00-00-710-074-A ** ON A/C NOT FOR ALL
A. Test.
(1) Not applicable.
4. Fault Isolation(1) Not applicable.
Subtask 77-00-00-810-062-A ** ON A/C NOT FOR ALL
A. The ECAM warning message ENG 1 EGT DISCREPANCY is generated if the cockpit indicated EGT and the EGT output selected from the ECU disagree.
(1) If the symptom ENG 1 EGT DISCREPANCY is not confirmed:
(a) No maintenance action is required.
(2) If the symptom ENG 1 EGT DISCREPANCY is repetitive or confirmed:
1 If damage is found:
Subtask 77-00-00-810-062-B ** ON A/C NOT FOR ALL (1) If the symptom ENG 1 EGT DISCREPANCY is not confirmed:
(a) No maintenance action is required.
(2) If the symptom ENG 1 EGT DISCREPANCY is repetitive or confirmed:
- disconnect the CJ13 harness from T49.5 junction box receptacle (located in the left core compartment).
1 If damage is found:
- repair or replace as required.
- do a cleaning of the connector and receptacle using a BRUSH - BRISTLED with stoddard solvent (Material No.CP2011) AMM 73-21-50-210-001.
- replace the EGT thermocouple AMM 77-21-10-000-002 AMM 77-21-10-400-002.
- replace the extension leads of the CJ13 harness AMM 77-21-10-000-001 and AMM 77-21-10-400-001.
A. The ECAM warning message ENG 1 EGT DISCREPANCY is generated if the cockpit indicated EGT and the EGT output selected from the ECU disagree.
(1) Disconnect harnesses from the EGT sensor receptacles, HJ13 and CJ13 (upper right hand and left hand thermocouple connectors, lower left hand and right hand thermocouple connectors).
(a) Visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-002.
1 If damage is found:
(a) Visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-002.
1 If damage is found:
Subtask 77-00-00-710-075-A ** ON A/C NOT FOR ALL (1) Disconnect harnesses from the EGT sensor receptacles, HJ13 and CJ13 (upper right hand and left hand thermocouple connectors, lower left hand and right hand thermocouple connectors).
(a) Visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-002.
1 If damage is found:
- repair or replace as required.
- do a cleaning of the connector and receptacle using a BRUSH - BRISTLED with stoddard solvent (Material No.CP2011) AMM 73-21-50-210-002.
(a) Visually examine the receptacle and the connector for damaged pins or contamination AMM 73-21-50-210-002.
1 If damage is found:
- repair or replace as required.
- do a cleaning of the connector and receptacle using a BRUSH - BRISTLED with stoddard solvent (Material No.CP2011) AMM 73-21-50-210-002.
- replace the EGT thermocouple AMM 77-21-10-000-025 AMM 77-21-10-400-025.
- replace the extension leads of the CJ13 and HJ13 harnesses AMM 77-21-10-000-008 and AMM 77-21-10-400-008.
B. No additionnal maintenance action is required if the fault is not confirmed.
(1) Repeat the fault isolation procedure if the fault continues.
(1) Repeat the fault isolation procedure if the fault continues.