Loss of the ADIRU1 and ADIRU2 Data on Engine 1
1. Possible Causes
· ADIRU-1 ( 1FP1 )
· ADIRU-2 ( 1FP2 )
· EEC ( 4000KS )
2 Job Set-up Information
A. Referenced Information
REFERENCE DESIGNATION
73-20-00-810-891-A Loss of the ADIRU1 Data on Engine 1
73-20-00-810-893-A Loss of the ADIRU2 Data on Engine 1
Ref. AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power
Ref. AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External
Power
Ref. AMM 31-60-00-860-002 EIS Stop Procedure
Ref. AMM 34-12-34-000-001 Removal of the ADIRU
Ref. AMM 34-12-34-400-001 Installation of the ADIRU
Ref. AMM 71-00-00-710-022 Test No.6 : ELectronic Engine Control (EEC) System Idle Test
Ref. AMM 71-13-00-410-010 Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
Ref. AMM 73-22-34-000-010 Removal of the Electronic Engine Control (EEC)
Ref. AMM 73-22-34-400-010 Installation of the Electronic Engine Control (EEC)
3. Fault Confirmation
Subtask 77-00-00-860-062-A
A. Job Set-up
(1) Energize the aircraft electrical circuits
Ref. AMM 24-41-00-861-002 .
(2) On the panel 50VU, release the ENG/FADEC GND PWR/1 pushbutton switch.
Subtask 77-00-00-710-066-A
B. Test
(1) On the panel 50VU, push the ENG/FADEC GND PWR/1 pushbutton switch and then release it.
NOTE: This action resets the FADEC memory.
(2) Do the test No. 6: Electronic Engine Control (EEC1) system idle test Ref. AMM 71-00-00-710-022 .
(3) Read the LAST LEG REPORT of the FADEC (1A and 1B) menu on the MCDU (Ref. 70-00-00 Page
Block 301 Task Supporting Data) and make a record of the maintenance message.
4. Fault Isolation
Subtask 77-00-00-810-143-A
A. If the test gives the maintenance message :
· ADIRS1/ADIRS2/EEC1 and
· ADIRS1/HC/EEC1
Do the the trouble shooting procedure (Ref. TSM 73-20-00-810-891) .
Subtask 77-00-00-810-144-A
B. If the test gives the maintenance message :
· ADIRS1/ADIRS2/EEC1 and
· ADIRS2/HC/EEC1
Do the the trouble shooting procedure (Ref. TSM 73-20-00-810-893) .
Subtask 77-00-00-810-058-A
C. If the test gives the maintenance message ADIRS1 ADIRS2/EEC1:
· replace the ADIRU-1 ( 1FP1 ) Ref. AMM 34-12-34-000-001 and Ref. AMM 34-12-34-400-001 .
(1) If the fault continues:
· replace the ADIRU-2 ( 1FP2 ) Ref. AMM 34-12-34-000-001 and Ref. AMM 34-12-34-400-001 .
(2) If the fault continues:
· replace the EEC ( 4000KS ) Ref. AMM 73-22-34-000-010 and Ref. AMM 73-22-34-400-010 .
Subtask 77-00-00-710-067-A
D. Do the test given in Para. 3.
5. Close-up
Subtask 77-00-00-860-063-A
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
Ref. AMM 31-60-00-860-002 .
(2) On the panel 50VU, push the ENG/FADEC GND PWR/1 pushbutton switch.
(3) De-energize the aircraft electrical circuits
Ref. AMM 24-41-00-862-002 .
(4) Make sure that the fan cowls 437AL and 438AR are closed Ref. AMM 71-13-00-410-010 . [Rev.6 from Feb 2017] 2026.04.04 04:37:48 UTC