Nacelle Temperature Higher than the Limit on Engine 2



1. Possible Causes
· SENSOR-NACELLE TEMPERATURE ( 4008KS )
· Diffuser Case Tubes Seal
2 Job Set-up Information
A. Referenced Information
REFERENCE DESIGNATION
Ref. AMM 36-11-49-200-010 General Check of the Bleed-Air Ducts
Ref. AMM 72-42-10-000-001 Removal of the Diffuser Case Tubes Seal Rings from an Assembled
Engine
Ref. AMM 72-42-10-400-001 Installation of the Diffuser Case Tubes Seal Rings from an Assembled
Engine
Ref. AMM 75-41-15-000-010 Removal of the Nacelle Temperature Sensor
Ref. AMM 75-41-15-400-010 Installation of the Nacelle Temperature Sensor
3. Fault Confirmation
Subtask 77-00-00-710-096-A
A. Test
Not applicable.
4. Fault Isolation
Subtask 77-00-00-810-073-A
A. If the fault symptom is identified by the ECAM advisory ENG2 - NACELLE TEMP on the ENGINE page:
· examine the nacelle bleed valve ducts for damage or leaks Ref. AMM 36-11-49-200-010 .
(1) If you find no fault:
· replace the SENSOR-NACELLE TEMPERATURE ( 4008KS ) Ref. AMM 75-41-15-000-010 and
Ref. AMM 75-41-15-400-010 .
· reolace the Diffuser Case Tubes Seal Ref. AMM 72-42-10-000-001 and Ref.
AMM 72-42-10-400-001 [Rev.6 from Feb 2017] 2026.04.04 04:37:48 UTC