W DOC AIRBUS | TSM A320F

Failure of the EIU 1 circuit


TASK 76-12-00-810-836-A
Failure of the EIU 1 circuit


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 73-25-34-710-040
Operational Test of the Engine Interface Unit
AMM 73-25-34-710-043
Operational Test of the Engine Interface Unit
3. Fault Confirmation
Subtask 76-12-00-710-116-A ** ON A/C NOT FOR ALL
A. Do the operational test of the Engine Interface Unit (EIU) through the Centralized Fault Display System (CFDS) AMM 73-25-34-710-040.
Subtask 76-12-00-710-116-B ** ON A/C NOT FOR ALL
A. Do the operational test of the Engine Interface Unit (EIU) through the Centralized Fault Display System (CFDS) AMM 73-25-34-710-043.
4. Fault Isolation
Subtask 76-12-00-810-086-A ** ON A/C NOT FOR ALL
A. If the test gives a maintenance message, do the associated troubleshooting procedure.
Subtask 76-12-00-810-086-B ** ON A/C NOT FOR ALL
A. If the test gives a maintenance message, do the associated troubleshooting procedure.