Failure of the EIU 1 circuit
TASK 76-12-00-810-836-A
Failure of the EIU 1 circuit
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 76-12-00-710-116-A ** ON A/C NOT FOR ALL
Subtask 76-12-00-810-086-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:37:28 UTC
Failure of the EIU 1 circuit
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 73-25-34-710-040 | Operational Test of the Engine Interface Unit |
| AMM 73-25-34-710-043 | Operational Test of the Engine Interface Unit |
Subtask 76-12-00-710-116-A ** ON A/C NOT FOR ALL
A. Do the operational test of the Engine Interface Unit (EIU) through the Centralized Fault Display System (CFDS) AMM 73-25-34-710-040.
Subtask 76-12-00-710-116-B ** ON A/C NOT FOR ALL A. Do the operational test of the Engine Interface Unit (EIU) through the Centralized Fault Display System (CFDS) AMM 73-25-34-710-043.
4. Fault IsolationSubtask 76-12-00-810-086-A ** ON A/C NOT FOR ALL
A. If the test gives a maintenance message, do the associated troubleshooting procedure.
Subtask 76-12-00-810-086-B ** ON A/C NOT FOR ALL A. If the test gives a maintenance message, do the associated troubleshooting procedure.