TRA Signal Failure Channel A and B
TASK 76-11-00-810-836-A
TRA Signal Failure Channel A and B
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 76-11-00-710-104-A ** ON A/C NOT FOR ALL
Subtask 76-11-00-810-100-A ** ON A/C NOT FOR ALL
Subtask 76-11-00-860-057-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:37:29 UTC
TRA Signal Failure Channel A and B
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 73-11-00-810-825-A | Integrated Fuel Pump and Control/Protection TM Electrical Failure Channel B |
| TSM TASK 73-11-00-810-826-A | Fuel Filter Efficiency Degraded |
Subtask 76-11-00-710-104-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault IsolationSubtask 76-11-00-810-100-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
(1) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-825).
(2) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-826).
5. Close-up(1) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-825).
(2) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-826).
Subtask 76-11-00-860-057-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(1) Make sure that the work area is clean and clear of tools and other items.