W DOC AIRBUS | TSM A320F

TRA Signal Failure Channel A and B


TASK 76-11-00-810-836-A
TRA Signal Failure Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 73-11-00-810-825-A
Integrated Fuel Pump and Control/Protection TM Electrical Failure Channel B
TSM TASK 73-11-00-810-826-A
Fuel Filter Efficiency Degraded
3. Fault Confirmation
Subtask 76-11-00-710-104-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 76-11-00-810-100-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-825).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 73-11-00-810-826).
5. Close-up
Subtask 76-11-00-860-057-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:37:29 UTC