W DOC AIRBUS | TSM A320F

Nacelle Temperature above 310 deg.C (590 deg.F) or Loss of the Nacelle Temperature Data on Engine 2


TASK 75-41-00-810-808-A
Nacelle Temperature above 310 deg.C (590 deg.F) or Loss of the Nacelle Temperature Data on Engine 2


1. Possible Causes
  • SENSOR-TEMP, ENG 2 NACELLE [13KS2]
  • EIU-2 [1KS2]
  • aircraft wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 75-41-00-810-806-A
High Nacelle Temperature Indication on Engine 2
ASM 732507
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
AMM 73-25-34-710-040
Operational Test of the Engine Interface Unit
AMM 73-25-34-710-043
Operational Test of the Engine Interface Unit
AMM 75-41-15-000-040
Removal Nacelle Temperature Sensor
AMM 75-41-15-000-041
Removal of the Nacelle Temperature Sensor
AMM 75-41-15-400-040
Installation Nacelle Temperature Sensor
AMM 75-41-15-400-041
Installation of the Nacelle Temperature Sensor
3. Fault Confirmation
Subtask 75-41-00-710-064-A ** ON A/C NOT FOR ALL
A. Test
   (1) Check the Post Flight Report (PFR), crew report and do the operational test of the Engine Interface Unit (EIU) through the Centralized Fault Display System (CFDS) AMM 73-25-34-710-040.
Subtask 75-41-00-710-064-B ** ON A/C NOT FOR ALL
A. Test
   (1) Check the Post Flight Report (PFR), crew report and do the operational test of the Engine Interface Unit (EIU) through the Centralized Fault Display System (CFDS) AMM 73-25-34-710-043.
4. Fault Isolation
Subtask 75-41-00-810-057-A ** ON A/C NOT FOR ALL
A. If the maintenance message CHECK HOT AIR LEAKS is shown at the end of test or in the Post Flight Report (PFR) or if the crew reported that nacelle temperature was flashing on ECAM:
   (1) If nothing is confirmed:
   (2) If the fault continues:
  • do a check of the electrical wiring between the EIU-2 [1KS2] and the nacelle temperature sensor (13KS2) ASM 732507, wiring resistance must be lower than 2.4 ohms.
     (a) Check the electrical connectors for absence of contamination, corrosion or loose pins:
  • clean or repair aircraft wiring as required.
   (3) If the fault continues:
Subtask 75-41-00-810-057-B ** ON A/C NOT FOR ALL
A. If the maintenance message CHECK HOT AIR LEAKS is shown at the end of test or in the Post Flight Report (PFR) or if the crew reported that nacelle temperature was flashing on ECAM:
   (1) If nothing is confirmed:
   (2) If the fault continues:
  • do a check of the electrical wiring between the EIU-2 [1KS2] and the nacelle temperature sensor (13KS2) ASM 732507, wiring resistance must be lower than 2.4 ohms.
     (a) Check the electrical connectors for absence of contamination, corrosion or loose pins:
  • clean or repair aircraft wiring as required.
   (3) If the fault continues:
Subtask 75-41-00-710-065-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
   (1) No additional maintenance action is required if the fault is not confirmed.
   (2) Repeat the fault isolation procedure if the fault continues.
[Rev.8 from Aug 2018] 2026.04.04 04:37:13 UTC