LPC SVA - LVDT Electrical Failure on Channel A and B
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 75-31-01-710-056-A ** ON A/C NOT FOR ALL
Subtask 75-31-01-810-078-A ** ON A/C NOT FOR ALL
Subtask 75-31-01-860-054-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:37:21 UTC
LPC SVA - LVDT Electrical Failure on Channel A and B
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 75-31-01-810-801-A | LPC SVA - LVDT Electrical Failure Channel A |
| TSM TASK 75-31-01-810-802-A | LPC SVA - LVDT Electrical Failure Channel B |
Subtask 75-31-01-710-056-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault IsolationSubtask 75-31-01-810-078-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
(1) Do the troubleshooting procedure (Ref. TSM TASK 75-31-01-810-801).
(2) Do the troubleshooting procedure (Ref. TSM TASK 75-31-01-810-802).
5. Close-up(1) Do the troubleshooting procedure (Ref. TSM TASK 75-31-01-810-801).
(2) Do the troubleshooting procedure (Ref. TSM TASK 75-31-01-810-802).
Subtask 75-31-01-860-054-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(1) Make sure that the work area is clean and clear of tools and other items.