W DOC AIRBUS | TSM A320F

HPC SVA Master Actuator / TM Electrical Failure on Channel A and B


TASK 75-31-00-810-844-A
HPC SVA Master Actuator / TM Electrical Failure on Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 75-31-00-810-807-A
HPC SVA Master Actuator/Torque Motor (TM) Electrical Failure Channel A
TSM TASK 75-31-00-810-815-A
HPC SVA Master Actuator/Torque Motor (TM) Electrical Failure Channel B
3. Fault Confirmation
Subtask 75-31-00-710-088-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 75-31-00-810-124-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure (Ref. TSM TASK 75-31-00-810-807).
   (2) Do the troubleshooting procedure (Ref. TSM TASK 75-31-00-810-815).
5. Close-up
Subtask 75-31-00-860-078-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:37:21 UTC