Failure of the Control of the Variable Bleed Valve (VBV) Actuator on Engine 2 - Channel B
TASK 75-30-00-810-838-A
Failure of the Control of the Variable Bleed Valve (VBV) Actuator on Engine 2 - Channel B
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 75-30-00-710-144-A ** ON A/C NOT FOR ALL
Subtask 75-30-00-810-099-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:37:10 UTC
Failure of the Control of the Variable Bleed Valve (VBV) Actuator on Engine 2 - Channel B
1. Possible Causes
- flexible shaft
- VBV ballscrew actuator
- VBV gear motor
- VBV stop mechanism assembly
- main flexible shaft
- VBV master ballscrew actuator
VBV sensor (RVDT) - ECU [4000KS]
- VBV stop mechanism
- VBV master door actuator
- HMU-2 [4000KC2]
- harness J8
- flexible shafts
- harness HJ8
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| 79001209-1 | 2 | HONEYWELL TOOLING |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 73-21-10-000-001 | Removal of the Hydromechanical Unit (HMU) |
| AMM 73-21-10-000-002 | Removal of the Hydromechanical Unit (HMU) |
| AMM 73-21-10-400-001 | Installation of the Hydromechanical Unit (HMU) |
| AMM 73-21-10-400-002 | Installation of the Hydromechanical Unit (HMU) |
| AMM 73-21-50-000-007 | Removal of J8 Harness |
| AMM 73-21-50-000-041 | Removal of the HJ8 Harness for SAC Engines |
| AMM 73-21-50-210-001 | Visual Inspection of the Wiring Harness |
| AMM 73-21-50-210-002 | Visual Inspection of the Wiring Harnesses |
| AMM 73-21-50-400-007 | Installation of the J8 Harness |
| AMM 73-21-50-400-041 | Installation of the HJ8 Harness for SAC Engines |
| AMM 73-21-60-000-001 | Removal of the Electronic Control Unit (ECU) |
| AMM 73-21-60-400-001 | Installation of the Electronic Control Unit (ECU) |
| AMM 73-29-00-710-040 | Operational Test of the FADEC on the ground (with Engine Motoring) |
| AMM 75-31-00-200-001 | Manual Operation Check of the Variable Bleed Valve Doors |
| AMM 75-31-00-200-002 | Manual Operation Check of the Variable Bleed Valve Doors |
| AMM 75-31-00-640-801 | Re-greasing of the Variable Bleed Valve (VBV) System |
| AMM 75-31-10-000-001 | Removal of the Bleed Valve Fuel Gear Motor Assembly |
| AMM 75-31-10-000-002 | Removal of the Bleed Valve Fuel Gear Motor Assembly |
| AMM 75-31-10-400-001 | Installation of the Bleed Valve Fuel Gear Motor Assembly |
| AMM 75-31-10-400-002 | Installation of the Bleed Valve Fuel Gear Motor Assembly |
| AMM 75-31-20-000-001 | Removal of the Bleed Valve Stop Mechanism |
| AMM 75-31-20-000-002 | Removal of the Bleed Valve Stop Mechanism |
| AMM 75-31-20-400-001 | Installation of the Bleed Valve Stop Mechanism |
| AMM 75-31-20-400-002 | Installation of the Bleed Valve Stop Mechanism |
| AMM 75-31-30-000-001 | Removal of a VBV Inter-connecting Flexible Shaft (Typical). |
| AMM 75-31-30-000-002 | Removal of the VBV System Main Flexible Shaft |
| AMM 75-31-30-000-003 | Removal of a VBV Inter-connecting Flexible Shaft (Typical) |
| AMM 75-31-30-000-004 | Removal of the VBV System Main Flexible Shaft |
| AMM 75-31-30-200-001 | Visual Inspection of the VBV Main Flexible Shaft and the VBV Inter-connecting Flexible Shafts |
| AMM 75-31-30-200-002 | Visual Inspection of the VBV Main Flexible Shaft and the VBV Inter-connecting Flexible Shafts |
| AMM 75-31-30-400-001 | Installation of a VBV Inter-connecting Flexible Shaft (Typical) |
| AMM 75-31-30-400-002 | Installation of the VBV System Main Flexible Shaft |
| AMM 75-31-30-400-003 | Installation of a VBV Inter-connecting Flexible Shaft (Typical) |
| AMM 75-31-30-400-004 | Installation of the VBV System Main Flexible Shaft |
| AMM 75-31-50-000-001 | Removal of the Bleed Valve and Master Ballscrew Actuator |
| AMM 75-31-50-000-002 | Removal of the Bleed Valve and Master Ballscrew Actuator Assembly |
| AMM 75-31-50-400-001 | Installation of the Bleed Valve and Master Ballscrew Actuator |
| AMM 75-31-50-400-002 | Installation of the Bleed Valve and Master Ballscrew Actuator Assembly |
| AMM 75-31-60-000-001 | Removal of the Bleed Valve and Ballscrew Actuator Assembly |
| AMM 75-31-60-000-002 | Removal of the Bleed Valve and Ballscrew Actuator Assembly |
| AMM 75-31-60-400-001 | Installation of the Bleed Valve and Ballscrew Actuator Assembly |
| AMM 75-31-60-400-002 | Installation of the Bleed Valve and Ballscrew Actuator Assembly |
| AMM 75-31-70-000-001 | Removal of the Variable Bleed Valve Position Sensor |
| AMM 75-31-70-000-002 | Removal of the Variable Bleed Valve position Sensor |
| AMM 75-31-70-400-001 | Installation of the Variable Bleed Valve Position Sensor |
| AMM 75-31-70-400-002 | Installation of the Variable Bleed Valve position Sensor |
Subtask 75-30-00-710-144-A ** ON A/C NOT FOR ALL
A. Do the operational test of FADEC 2B on the ground (with engine motoring) AMM 73-29-00-710-040.
4. Fault IsolationNOTE: The failure message is generated if the actual position and the demanded position of the VBV system disagree (only the position of VBV master actuator door is monitored).
NOTE: There is no expected position of the VBV actuators on a non-running engine. The position of the VBV actuators must be uniform but can be either open, closed or intermediate.
Subtask 75-30-00-810-099-A ** ON A/C NOT FOR ALL
A. If the FADEC test does not give the maintenance message "VBV ACT, HMU":
(a) Remove all the flexible shafts AMM 75-31-30-000-003.
(b) Inspect each flexible shaft AMM 75-31-30-200-001. If not serviceable, replace any flexible shaft AMM 75-31-30-000-003 and AMM 75-31-30-400-003.
(c) Manually operate each of the 11 VBV actuators in both directions and make sure that each actuator moves smoothly and freely.
(a) Do a check of the rigging of the feedback rod to the VBV position sensor (RVDT) AMM 75-31-70-400-001.
(b) Remove the VBV gear motor/stop mechanism assembly AMM 75-31-10-000-001.
(c) Manually check for free rotation of the VBV gear motor. If it does not move freely, replace the VBV gear motor AMM 75-31-10-000-001 and AMM 75-31-10-400-001.
(d) Manually check for free rotation of the stop mechanism. Using the main flexible shaft, check for full travel of the nut follower by turning the main flexible shaft counterclockwise and clockwise until the follower nut is against the mechanical stop. If it does not move freely, replace the VBV stop mechanism assembly AMM 75-31-20-000-001 and AMM 75-31-20-400-001.
(e) Inspect the main flexible shaft AMM 75-31-30-200-001. If not serviceable, replace the main flexible shaft AMM 75-31-30-000-004 and AMM 75-31-30-400-004.
(f) Remove all the flexible shafts AMM 75-31-30-000-003.
(g) Inspect each flexible shaft AMM 75-31-30-200-001. If not serviceable, replace any flexible shaft AMM 75-31-30-000-003 and AMM 75-31-30-400-003. If the flexible shaft are not serviceable, all the VBV doors must be inspected and manually operated.
(h) Manually operate each of the 11 VBV actuators in both directions and make sure that each actuator moves smoothly and freely.
. Replace theVBV sensor (RVDT) AMM 75-31-70-000-001 and AMM 75-31-70-400-001.
2 If the fault continues during the subsequent flight:
Subtask 75-30-00-810-111-A ** ON A/C NOT FOR ALL - Do a visual inspection of all the VBV door actuators and flexible shafts, check for an offset of position between all the VBV doors with fan frame (all the VBV doors not set in the same position):
(a) Remove all the flexible shafts AMM 75-31-30-000-003.
(b) Inspect each flexible shaft AMM 75-31-30-200-001. If not serviceable, replace any flexible shaft AMM 75-31-30-000-003 and AMM 75-31-30-400-003.
(c) Manually operate each of the 11 VBV actuators in both directions and make sure that each actuator moves smoothly and freely.
- During this check, slightly open the VBV doors with the hexagonal end, then take the VBV plate door by hand and open and close the VBV door by applying a manual force on the door,
- If any binding or sticking point is noted or if any VBV door is found hard to rotate, do a backdriving test using 79001209-1 HONEYWELL TOOLING or equivalent to check that the force necessary to open the VBV door is not more than 60 lbf (26.69 daN),
- If the force to open the VBV door is more than 60 lbf (26.69 daN), replace the VBV ballscrew actuator AMM 75-31-60-000-001 and AMM 75-31-60-400-001.
(a) Do a check of the rigging of the feedback rod to the VBV position sensor (RVDT) AMM 75-31-70-400-001.
(b) Remove the VBV gear motor/stop mechanism assembly AMM 75-31-10-000-001.
(c) Manually check for free rotation of the VBV gear motor. If it does not move freely, replace the VBV gear motor AMM 75-31-10-000-001 and AMM 75-31-10-400-001.
(d) Manually check for free rotation of the stop mechanism. Using the main flexible shaft, check for full travel of the nut follower by turning the main flexible shaft counterclockwise and clockwise until the follower nut is against the mechanical stop. If it does not move freely, replace the VBV stop mechanism assembly AMM 75-31-20-000-001 and AMM 75-31-20-400-001.
(e) Inspect the main flexible shaft AMM 75-31-30-200-001. If not serviceable, replace the main flexible shaft AMM 75-31-30-000-004 and AMM 75-31-30-400-004.
(f) Remove all the flexible shafts AMM 75-31-30-000-003.
(g) Inspect each flexible shaft AMM 75-31-30-200-001. If not serviceable, replace any flexible shaft AMM 75-31-30-000-003 and AMM 75-31-30-400-003. If the flexible shaft are not serviceable, all the VBV doors must be inspected and manually operated.
(h) Manually operate each of the 11 VBV actuators in both directions and make sure that each actuator moves smoothly and freely.
- During this check, slightly open the VBV doors with the hexagonal end, then take the VBV plate door by hand and open and close the VBV door by applying a manual force on the door,
- If any binding or sticking point is noted or if any VBV door is found hard to rotate, do a backdriving test using 79001209-1 HONEYWELL TOOLING or equivalent and pull scale to check that the force necessary to open the VBV door is not more than 60 lbf (26.69 daN),
- If the force to open the VBV door is more than 60 lbf (26.69 daN), replace the VBV ballscrew actuator AMM 75-31-60-000-001 and AMM 75-31-60-400-001.
- During this check, slightly open the VBV master door with the hexagonal end, then take the VBV plate door by hand and open and close the VBV master door by applying a manual force on the door,
- If any binding or sticking is noted or if the VBV master door is found hard to rotate, do a backdriving test using 79001209-1 HONEYWELL TOOLING or equivalent and pull scale to check that the force necessary to open the VBV master door is not more than 90 lbf (40.03 daN),
- If the force to open the VBV master door is more than 90 lbf (40.03 daN), replace the VBV master ballscrew actuator AMM 75-31-50-000-001 and AMM 75-31-50-400-001.
- Disconnect the harness J8 from the ECU receptacle and visually examine the receptacle and the connector for pins in poor condition or contamination AMM 73-21-50-210-001.
- Disconnect the harness J8 connector from the HMU receptacle and visually examine the receptacle and the connector for pins in poor condition or contamination AMM 73-21-50-210-001.
- If the VBV gear motor Part Number is 396800-7 or 396800-9 replace the VBV gear motor , AMM 75-31-10-000-001 and AMM 75-31-10-400-001.
- If not:
. Replace the
2 If the fault continues during the subsequent flight:
- Replace the ECU [4000KS] AMM 73-21-60-000-001 and AMM 73-21-60-400-001.
B. If the test gives the maintenance message VBV ACT, HMU:
(1) Do a visual inspection of all the VBV door actuators and flexible shafts through the fan duct panels, check for an offset of position between all the VBV doors (all the VBV doors not set in the same positon):
(a) If the system is hard to rotate or does not move freely (non-constant torque) or is an offset of position is observed between the VBV doors:
a Check for free rotation of the VBV gear motor. If it does not move freely, replace the VBV gear motor AMM 75-31-10-000-001 and AMM 75-31-10-400-001.
b Check for free rotation of the stop mechanism. Using the main flexible shaft, check for full travel of the nut follower by turning the main flexible shaft counterclockwise and clockwise until the follower nut is against the mechanical stop. If it does not move freely, replace the VBV stop mechanism AMM 75-31-20-000-001 and AMM 75-31-20-400-001.
c Check for free rotation of the VBV master door actuator. If it does not move freely, replace the VBV master door actuator AMM 75-31-50-000-001 and AMM 75-31-50-400-001.
2 Inspect the main flexible shaft AMM 75-31-30-200-001. If not serviceable, replace the main flexible shaft in case of excessive wear AMM 75-31-30-000-004 and AMM 75-31-30-400-004.
3 Remove all the flexible shafts AMM 75-31-30-000-003.
a Inspect each flexible shaft AMM 75-31-30-200-001. If not serviceable, replace any flexible shaft AMM 75-31-30-000-003 and AMM 75-31-30-400-003. In case of wear on the flexible shaft, all the VBV doors must be inspected and manually operated.
b Manually operate each of the 11 VBV actuators in both directions and make sure that each moves smoothly and freely.
2 Do an electrical resistance check through the J8 harness between:
. Pins 29 and 30 (17 to 23 Ohms).
a If the resistance value is in the specified limits:
Subtask 75-30-00-810-099-B ** ON A/C NOT FOR ALL (1) Do a visual inspection of all the VBV door actuators and flexible shafts through the fan duct panels, check for an offset of position between all the VBV doors (all the VBV doors not set in the same positon):
- If an offset between VBV doors or finding to VBV flexible shafts is observed, do an inspection of the VBV doors, go to the Para. 4.A.(1).
(a) If the system is hard to rotate or does not move freely (non-constant torque) or is an offset of position is observed between the VBV doors:
- Operate each of the 11 VBV actuators in both directions and make sure that each moves smoothly and freely.
NOTE: During this check, apply a manual load tending to force the door towards its open position. Replace any suspect VBV ballscrew actuator AMM 75-31-60-000-001 and AMM 75-31-60-400-001.
1 Remove the VBV gear motor/stop mechanism assembly AMM 75-31-10-000-001. a Check for free rotation of the VBV gear motor. If it does not move freely, replace the VBV gear motor AMM 75-31-10-000-001 and AMM 75-31-10-400-001.
b Check for free rotation of the stop mechanism. Using the main flexible shaft, check for full travel of the nut follower by turning the main flexible shaft counterclockwise and clockwise until the follower nut is against the mechanical stop. If it does not move freely, replace the VBV stop mechanism AMM 75-31-20-000-001 and AMM 75-31-20-400-001.
c Check for free rotation of the VBV master door actuator. If it does not move freely, replace the VBV master door actuator AMM 75-31-50-000-001 and AMM 75-31-50-400-001.
2 Inspect the main flexible shaft AMM 75-31-30-200-001. If not serviceable, replace the main flexible shaft in case of excessive wear AMM 75-31-30-000-004 and AMM 75-31-30-400-004.
3 Remove all the flexible shafts AMM 75-31-30-000-003.
a Inspect each flexible shaft AMM 75-31-30-200-001. If not serviceable, replace any flexible shaft AMM 75-31-30-000-003 and AMM 75-31-30-400-003. In case of wear on the flexible shaft, all the VBV doors must be inspected and manually operated.
b Manually operate each of the 11 VBV actuators in both directions and make sure that each moves smoothly and freely.
- During this check, slightly open the VBV master door with the hexagonal end, then take the VBV plate door by hand and open and close the VBV master door by applying a manual force on the door,
- If any binding or sticking is noted or if the VBV master door is found hard to rotate, do a backdriving test using 79001209-1 HONEYWELL TOOLING or equivalent and pull scale to check that the force necessary to open the VBV master door is not more than 90 lbf (40.03 daN),
- If the force to open the VBV master door is more than 90 lbf (40.03 daN), replace the VBV master ballscrew actuator AMM 75-31-50-000-001 and AMM 75-31-50-400-001.
- During this check, slightly open the VBV master door with the hexagonal end, then take the VBV plate door by hand and open and close the VBV master door by applying a manual force on the door,
- If any binding or sticking is noted or if the VBV master door is found hard to rotate, do a backdriving test using 79001209-1 HONEYWELL TOOLING or equivalent and pull scale to check that the force necessary to open the VBV master door is not more than 90 lbf (40.03 daN),
- If the force to open the VBV master door is more than 90 lbf (40.03 daN), replace the VBV master ballscrew actuator AMM 75-31-50-000-001 and AMM 75-31-50-400-001.
- Disconnect harness J8 from the ECU receptacle:
2 Do an electrical resistance check through the J8 harness between:
. Pins 29 and 30 (17 to 23 Ohms).
a If the resistance value is in the specified limits:
- Replace the HMU-2 [4000KC2] AMM 73-21-10-000-001 and AMM 73-21-10-400-001.
- If the fault continues, replace the VBV sensor (RVDT) AMM 75-31-70-000-001 and AMM 75-31-70-400-001.
- If the fault continues, replace the ECU [4000KS] AMM 73-21-60-000-001 and AMM 73-21-60-400-001.
- Disconnect harness J8 from the HMU and visually examine the receptacle and connector for pins in poor condition or contamination AMM 73-21-50-210-001.
- Do a check of the HMU resistance between:
. Pins 29 and 30 (17 to 23 Ohms).
* If the resistance value is in the specified limits: - Replace the defective harness J8 AMM 73-21-50-000-007 and AMM 73-21-50-400-007, or
* If the resistance value is out of the specified limits: - Replace the HMU-2 [4000KC2] AMM 73-21-10-000-001 and AMM 73-21-10-400-001.
C. If the test does not give the maintenance message "VBV ACT, HMU":
(a) Remove all the flexible shafts AMM 75-31-30-000-001.
(b) Inspect each flexible shaft AMM 75-31-30-200-002. If not serviceable, replace any flexible shaft AMM 75-31-30-000-001 and AMM 75-31-30-400-001.
(c) Manually operate each of the 11 VBV actuators in both directions and make sure that each VBV actuator moves smoothly and freely.
(a) Do a check of the rigging of the feedback rod to the VBV position sensor (RVDT) AMM 75-31-70-400-002.
(b) Remove the VBV gear motor/stop mechanism assembly AMM 75-31-20-000-002.
(c) Manually check for free rotation of the VBV gear motor. If it does not move freely, replace the VBV gear motor AMM 75-31-10-000-002 and AMM 75-31-10-400-002.
(d) Manually check for free rotation of the stop mechanism. Using the main flexible shaft, check for full travel of the nut follower by turning the main flexible shaft counterclockwise and clockwise until the follower nut is against the mechanical stop. If it does not move freely, replace the VBV stop mechanism AMM 75-31-20-000-002 and AMM 75-31-20-400-002.
(e) Inspect the main flexible shaft AMM 75-31-30-200-002.
(f) Remove all the flexible shafts AMM 75-31-30-000-001.
(g) Inspect each flexible shaft AMM 75-31-30-200-002. If not serviceable replace flexible shaft AMM 75-31-30-000-001 and AMM 75-31-30-400-001 as necessary. If the flexible shafts are not serviceable, all the VBV doors must be inspected and manually operated.
(h) Manually operate each of the 11 VBV actuators in both directions and make sure that each VBV actuator moves smoothly and freely.
Subtask 75-30-00-810-111-B ** ON A/C NOT FOR ALL - Do a visual inspection of all VBV door actuators and flexible shafts, check for an offset of position between all the VBV doors with the fan frame (all the VBV doors not set in the same position).
(a) Remove all the flexible shafts AMM 75-31-30-000-001.
(b) Inspect each flexible shaft AMM 75-31-30-200-002. If not serviceable, replace any flexible shaft AMM 75-31-30-000-001 and AMM 75-31-30-400-001.
(c) Manually operate each of the 11 VBV actuators in both directions and make sure that each VBV actuator moves smoothly and freely.
- During this check, slightly open the VBV doors with the hexagonal end, then take the VBV plate door and open and close the VBV door by applying a manual force on the door.
- If any binding or sticking point is found or if any VBV door is found hard to rotate, do a back driving test using the 79001209-1 HONEYWELL TOOLING or equivalent to check that the force necessary to open the VBV door is not more than 60 lbf (26.69 daN).
- If the force to open the VBV door is not more than 60 lbf (26.69 daN), do a re-greasing of the VBV system AMM 75-31-00-640-801.
- If the force to open the VBV door is more than 60 lbf (26.69 daN), replace the VBV ballscrew actuator AMM 75-31-60-000-002 and AMM 75-31-60-400-002.
(a) Do a check of the rigging of the feedback rod to the VBV position sensor (RVDT) AMM 75-31-70-400-002.
(b) Remove the VBV gear motor/stop mechanism assembly AMM 75-31-20-000-002.
(c) Manually check for free rotation of the VBV gear motor. If it does not move freely, replace the VBV gear motor AMM 75-31-10-000-002 and AMM 75-31-10-400-002.
(d) Manually check for free rotation of the stop mechanism. Using the main flexible shaft, check for full travel of the nut follower by turning the main flexible shaft counterclockwise and clockwise until the follower nut is against the mechanical stop. If it does not move freely, replace the VBV stop mechanism AMM 75-31-20-000-002 and AMM 75-31-20-400-002.
(e) Inspect the main flexible shaft AMM 75-31-30-200-002.
(f) Remove all the flexible shafts AMM 75-31-30-000-001.
(g) Inspect each flexible shaft AMM 75-31-30-200-002. If not serviceable replace flexible shaft AMM 75-31-30-000-001 and AMM 75-31-30-400-001 as necessary. If the flexible shafts are not serviceable, all the VBV doors must be inspected and manually operated.
(h) Manually operate each of the 11 VBV actuators in both directions and make sure that each VBV actuator moves smoothly and freely.
- During this check, slightly open the VBV doors with the hexagonal end, then take the VBV plate door and open and close the VBV door by applying a manual force on the door.
- If any binding or sticking point is found or if any VBV door is found hard to rotate, do a back driving test using the 79001209-1 HONEYWELL TOOLING or equivalent and pull the scale to check that the force necessary to open the VBV door is not more than 60 lbf (26.69 daN).
- If the force to open the VBV door is not more than 60 lbf (26.69 daN), do a re-greasing of the VBV system AMM 75-31-00-640-801.
- If the force to open the VBV door is more than 60 lbf (26.69 daN), replace the VBV ballscrew actuator AMM 75-31-60-000-002 and AMM 75-31-60-400-002.
- During this check, slightly open the VBV master door with the hexagonal end, then take the VBV plate door by hand and open and close the VBV master door by applying a manual force on the door.
- If any binding or sticking is found or if the VBV master door is found hard to rotate, do a back driving test using the 79001209-1 HONEYWELL TOOLING or equivalent and pull the scale to check that the force necessary to open the VBV master door is not more than 90 lbf (40.03 daN).
- If the force to open the VBV master door is not more than 90 lbf (40.03 daN), do a re-greasing of the VBV System AMM 75-31-00-640-801.
- If the force to open the VBV master door is more than 90 lbf (40.03 daN), replace the VBV ballscrew actuator AMM 75-31-50-000-002 and AMM 75-31-50-400-002.
- Disconnect harness HJ8 from the ECU receptacle and visually examine the receptacle and the connector for pins in poor condition or contamination AMM 73-21-50-210-002.
- Disconnect harness HJ8 from the HMU receptacle and visually examine the receptacle and the connector for pins in poor condition or contamination AMM 73-21-50-210-002.
- Replace the VBV gear motor AMM 75-31-10-000-002 and AMM 75-31-10-400-002.
- Do a check of the Post Flight Report (PFR) and the Schedule Maintenance Report (SMR)/Class 3 report for the maintenance message(s) VBV SNSR, J11, ECU and/or VBV SNSR, J12, ECU.
- Replace the
VBV sensor (RVDT) AMM 75-31-70-000-002 and AMM 75-31-70-400-002.
- Replace the ECU [4000KS] AMM 73-21-60-000-001 and AMM 73-21-60-400-001.
D. If the test gives the maintenance message VBV ACT, HMU:
(1) Do a visual inspection of all the VBV door actuators and flexible shafts through the fan duct panels, check for an offset of position between all the VBV doors (all the VBV doors not set in the same positon).
(a) If the system is hard to rotate or does not move freely (the torque is not constant) or if an offset of position is observed between the VBV doors:
1 Remove the VBV gear motor/stop mechanism assembly AMM 75-31-10-000-002.
a Check for free rotation of the VBV gear motor. If it does not move freely, replace the VBV gear motor AMM 75-31-10-000-002 and AMM 75-31-10-400-002.
b Check for free rotation of the stop mechanism. Using the main flexible shaft, check for full travel of the nut follower by turning the main flexible shaft counterclockwise and clockwise until the follower nut is against the mechanical stop. If it does not move freely, replace the VBV stop mechanism AMM 75-31-20-000-002 and AMM 75-31-20-400-002.
2 Inspect the main flexible shaft AMM 75-31-30-200-002. If not serviceable, replace the main flexible shaft AMM 75-31-30-000-002 and AMM 75-31-30-400-002.
3 Remove all the flexible shafts AMM 75-31-30-000-001.
a Inspect each flexible shaft AMM 75-31-30-200-002. If not serviceable, replace the flexible shafts AMM 75-31-30-000-001 and AMM 75-31-30-400-001 as necessary. In case of finding on the flexible shafts, all the VBV doors must be inspected and manually operated.
b Manually operate each of the 11 VBV actuators in both directions and make sure that each VBV actuator moves smoothly and freely.
2 Do an electrical resistance check through the HJ8 harness between:
. Pins 29 and 30 (17 to 23 Ohms).
a If the resistance value is in the specified limits:
Subtask 75-30-00-710-145-A ** ON A/C NOT FOR ALL (1) Do a visual inspection of all the VBV door actuators and flexible shafts through the fan duct panels, check for an offset of position between all the VBV doors (all the VBV doors not set in the same positon).
- If an offset between VBV doors or finding to VBV flexible shafts is observed, do an inspection of the VBV doors, Refer to Para. 4.A.(1).
(a) If the system is hard to rotate or does not move freely (the torque is not constant) or if an offset of position is observed between the VBV doors:
1 Remove the VBV gear motor/stop mechanism assembly AMM 75-31-10-000-002.
a Check for free rotation of the VBV gear motor. If it does not move freely, replace the VBV gear motor AMM 75-31-10-000-002 and AMM 75-31-10-400-002.
b Check for free rotation of the stop mechanism. Using the main flexible shaft, check for full travel of the nut follower by turning the main flexible shaft counterclockwise and clockwise until the follower nut is against the mechanical stop. If it does not move freely, replace the VBV stop mechanism AMM 75-31-20-000-002 and AMM 75-31-20-400-002.
2 Inspect the main flexible shaft AMM 75-31-30-200-002. If not serviceable, replace the main flexible shaft AMM 75-31-30-000-002 and AMM 75-31-30-400-002.
3 Remove all the flexible shafts AMM 75-31-30-000-001.
a Inspect each flexible shaft AMM 75-31-30-200-002. If not serviceable, replace the flexible shafts AMM 75-31-30-000-001 and AMM 75-31-30-400-001 as necessary. In case of finding on the flexible shafts, all the VBV doors must be inspected and manually operated.
b Manually operate each of the 11 VBV actuators in both directions and make sure that each VBV actuator moves smoothly and freely.
- During this check, slightly open the VBV doors with the hexagonal end, then take the VBV plate door by hand and open and close the VBV door by applying a manual force on the door.
- If any binding or sticking point is found or if any VBV door is found hard to rotate, do a back driving test using the 79001209-1 HONEYWELL TOOLING or equivalent and pull the scale to check that the force necessary to open the VBV door is not more than 60 lbf (26.69 daN).
- If the force to open the VBV door is more than 60 lbf (26.69 daN), replace the VBV ballscrew actuator AMM 75-31-60-000-002 and AMM 75-31-60-400-002.
- If any binding or sticking is found, or if any VBV door is found hard to rotate, do a re-greasing of the VBV system AMM 75-31-00-640-801.
- During this check, slightly open the VBV master door with the hexagonal end, then take the VBV plate door by hand and open and close the VBV master door by applying a manual force on the door.
- If any binding or sticking is found or if the VBV master door is found hard to rotate, do a back driving test using the 79001209-1 HONEYWELL TOOLING or equivalent and the pull scale to check that the force necessary to open the VBV master door is not more than 90 lbf (40.03 daN).
- If the force to open the VBV master door is more than 90 lbf (40.03 daN), replace the VBV ballscrew actuator AMM 75-31-50-000-002 and AMM 75-31-50-400-002.
- If any binding or sticking is found, or if the VBV master door is found hard to rotate, do a re-greasing of the VBV system AMM 75-31-00-640-801.
- Disconnect harness HJ8 from the ECU receptacle:
2 Do an electrical resistance check through the HJ8 harness between:
. Pins 29 and 30 (17 to 23 Ohms).
a If the resistance value is in the specified limits:
- Replace the VBV gear motor AMM 75-31-10-000-002 and AMM 75-31-10-400-002.
- If the fault continues, replace the HMU-2 [4000KC2] AMM 73-21-10-000-002 and AMM 73-21-10-400-002.
- If the fault continues, replace the
VBV sensor (RVDT) AMM 75-31-70-000-002 and AMM 75-31-70-400-002. - If the fault continues, replace the ECU [4000KS] AMM 73-21-60-000-001 and AMM 73-21-60-400-001.
- Disconnect harness HJ8 from the HMU and visually examine the receptacle and connector for pins in poor condition or contamination AMM 73-21-50-210-002.
- Do a check of the HMU resistance between:
. Pins 29 and 30 (17 to 23 Ohms).
* If the resistance value is in the specified limits: - Replace the defective harness HJ8 AMM 73-21-50-000-041 and AMM 73-21-50-400-041, or
* If the resistance value is out of the specified limits: - Replace the HMU-2 [4000KC2] AMM 73-21-10-000-002 and AMM 73-21-10-400-002.
E. Do the test given in Para. 3.A.
(1) If the fault is not confirmed:
(1) If the fault is not confirmed:
- No additional maintenance action is necessary.
- Do the fault isolation procedure again.
VBV Actuator and Doors