W DOC AIRBUS | TSM A320F

Loss of the RAC Torque Motor Control through the two Channels on Engine 2


TASK 73-29-00-810-913-A
Loss of the RAC Torque Motor Control through the two Channels on Engine 2


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 73-29-00-810-882-A
Loss of the RAC Torque Motor Control through the Channel A on Engine 2
TSM TASK 73-29-00-810-883-A
Loss of the RAC Torque Motor Control through the Channel B on Engine 2
AMM 73-29-00-710-040
Operational Test of the FADEC on the ground (with Engine Motoring)
3. Fault Confirmation
Subtask 73-29-00-710-225-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the FADEC 2A and 2B on the ground (with engine motoring) AMM 73-29-00-710-040.
4. Fault Isolation
Subtask 73-29-00-810-205-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance messages J7, HMU (RAC TM), ECU and J8, HMU (RAC TM), ECU:
[Rev.8 from Aug 2018] 2026.04.04 04:36:02 UTC