W DOC AIRBUS | TSM A320F

All engine 2 parameters are not XX on the upper ECAM DU 5 minutes minimum after an engine shutdown on the ground


TASK 73-29-00-810-805-A
All engine 2 parameters are not XX on the upper ECAM DU 5 minutes minimum after an engine shutdown on the ground


1. Possible Causes
  • wiring between the ENG/MASTER CTL switch (2KC) and the EIU 2 (1KS2)
  • CTL SW-ENG/MASTER 2 [2KC]
  • EIU-2 [1KS2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2045210
ASM 732508
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
AMM 73-25-34-710-040
Operational Test of the Engine Interface Unit
AMM 73-25-34-710-043
Operational Test of the Engine Interface Unit
3. Fault Confirmation
Subtask 73-29-00-710-057-A ** ON A/C NOT FOR ALL
A. Test
   (1) Make sure that the engine 2 shutdown time was of 5 minutes minimum.
   (2) Do the operational test of the Engine Interface Unit AMM 73-25-34-710-040.
Subtask 73-29-00-710-057-B ** ON A/C NOT FOR ALL
A. Test
   (1) Make sure that the engine 2 shutdown time was of 5 minutes minimum.
   (2) Do the operational test of the Engine Interface Unit AMM 73-25-34-710-043.
4. Fault Isolation
Subtask 73-29-00-810-058-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message 115VU (MASTER LEVER 2SW):
  • Do a check and repair the wiring between the ENG/MASTER CTL switch (2KC) and the EIU 2 (1KS2), ASM 732508.
   (1) If the fault continues:
     (a) Replace the CTL SW-ENG/MASTER 2 [2KC] ESPM 2045210.
     (b) Do the operational test of the Engine Interface Unit AMM 73-25-34-710-040.
   (2) If the fault continues:
Subtask 73-29-00-810-059-A ** ON A/C NOT FOR ALL
B. If the test gives NO FAILURE message:
[Rev.8 from Aug 2018] 2026.04.04 04:35:51 UTC