W DOC AIRBUS | TSM A320F

All engine 1 parameters are not XX on the upper ECAM DU 5 minutes minimum after an engine shutdown on the ground


TASK 73-29-00-810-804-A
All engine 1 parameters are not XX on the upper ECAM DU 5 minutes minimum after an engine shutdown on the ground


1. Possible Causes
  • wiring between the ENG/MASTER CTL switch (3KC) and the EIU 1 (1KS1)
  • CTL SW-ENG/MASTER 1 [3KC]
  • EIU-1 [1KS1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2045210
ASM 732508
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
AMM 73-25-34-710-040
Operational Test of the Engine Interface Unit
AMM 73-25-34-710-043
Operational Test of the Engine Interface Unit
3. Fault Confirmation
Subtask 73-29-00-710-056-A ** ON A/C NOT FOR ALL
A. Test
   (1) Make sure that the engine 1 shutdown time was of 5 minutes minimum.
   (2) Do the operational test of the Engine Interface Unit AMM 73-25-34-710-040.
Subtask 73-29-00-710-056-B ** ON A/C NOT FOR ALL
A. Test
   (1) Make sure that the engine 1 shutdown time was of 5 minutes minimum.
   (2) Do the operational test of the Engine Interface Unit AMM 73-25-34-710-043.
4. Fault Isolation
Subtask 73-29-00-810-056-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message 115VU (MASTER LEVER 1SW):
  • do a check and repair the wiring between the ENG/MASTER CTL switch (3KC) and the EIU 1 (1KS1), ASM 732508.
   (1) If the fault continues:
     (a) Replace the CTL SW-ENG/MASTER 1 [3KC] ESPM 2045210.
     (b) Do the operational test of the Engine Interface Unit AMM 73-25-34-710-040.
   (2) If the fault continues:
Subtask 73-29-00-810-057-A ** ON A/C NOT FOR ALL
B. If the test gives NO FAILURE message:
[Rev.8 from Aug 2018] 2026.04.04 04:35:51 UTC