W DOC AIRBUS | TSM A320F

TR DCV 28 VDC not Available on Channel A and B


TASK 73-25-00-810-B44-A
TR DCV 28 VDC not Available on Channel A and B


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 73-25-00-810-A36-A
TR DCV 28 VDC Not Available on Channel A
TSM TASK 73-25-00-810-A37-A
TR DCV 28 VDC Not Available on Channel B
3. Fault Confirmation
Subtask 73-25-00-710-583-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 73-25-00-810-467-A ** ON A/C NOT FOR ALL
A. Do the two tasks as follows:
   (1) Do the troubleshooting procedure 73-25-00-810-A36 TSM TASK 73-25-00-810-A36-A.
   (2) Do the troubleshooting procedure 73-25-00-810-A37 TSM TASK 73-25-00-810-A37-A.
5. Close-up
Subtask 73-25-00-860-189-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:36:51 UTC