W DOC AIRBUS | TSM A320F

HPSOV Closed Fault on EIU-2


TASK 73-25-00-810-A92-A
HPSOV Closed Fault on EIU-2


1. Possible Causes
  • wiring
  • EIU-2 [1KS2]
  • CONT-AIR COND SYSTEM 1 [47HH]
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
MULTIMETER - STANDARD
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
AWM 216309
AMM 73-25-34-000-802
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-802
Installation of the Engine Interface Unit (EIU)
AMM 73-25-34-710-802
Operational Test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS)
AMM 73-25-34-860-803
Engine Interface Unit (EIU) DISCRETE OUTPUTS Simulation
3. Fault Confirmation
Subtask 73-25-00-710-531-A ** ON A/C NOT FOR ALL
A. Do the operational test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS) to confirm this fault AMM 73-25-34-710-802.
4. Fault Isolation
Subtask 73-25-00-810-393-A ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
   (1) Remove the air-conditioning system controller (47HH) AMM 21-61-34-000-002.
   (2) On the MCDU, simulate the Discrete Output (DSO) 9:
     (a) Push the adjacent button to DSO 9 to have the status equal to 1 AMM 73-25-34-860-803.
     (b) At controller rack connector (AB), use a MULTIMETER - STANDARD to do a check for ground at contact 1H AWM 216309.
       1 Stop the simulation of DSO 9 AMM 73-25-34-860-803.
   (3) If there is no ground, do a check of wiring between contact 1H and contact 1E at EIU-2 (1KS2) AWM 216309 for:
     (a) Continuity (less than 5 ohms resistance)
     (b) Short to ground.
       1 If you find damage, repair or replace wiring AWM 216309.
       2 If you find no damage:
         a Replace EIU-2 [1KS2] AMM 73-25-34-000-802 and AMM 73-25-34-400-802.
       3 Install the air-conditioning system controller (47HH) AMM 21-61-34-400-002.
       4 Do the test given in Para. 3.
   (4) If there is ground at contact 1H or if the fault continues:
     (a) Replace CONT-AIR COND SYSTEM 1 [47HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
     (b) Do the test given in Para. 3.
   (5) If the fault continues:
     (a) Replace EIU-2 [1KS2] AMM 73-25-34-000-802 and AMM 73-25-34-400-802.
     (b) Do the test given in Para. 3.
5. Close-up
Subtask 73-25-00-860-147-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:36:48 UTC