Ignitors A and B Supplies Fault on EIU-2


TASK 73-25-00-810-A45-A
Ignitors A and B Supplies Fault on EIU-2


1. Possible Causes
  • EIU-2 [1KS2]
  • aircraft wiring
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
MULTIMETER - STANDARD
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 73-25-34-000-802
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-802
Installation of the Engine Interface Unit (EIU)
AMM 73-25-34-710-802
Operational Test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS)
AWM 743101
AWM 743102
3. Fault Confirmation
Subtask 73-25-00-710-482-A ** ON A/C NOT FOR ALL
A. Do the test as follows:
   (1) Make sure the ENG/MASTER control switch (2KC) is in the OFF position.
   (2) Do the operational test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS) to confirm this fault AMM 73-25-34-710-802.
   (3) If the fault is confirmed go to the Para. 4.
   (4) If the fault is not confirmed, put the ENG/MASTER control switch (2KC) in the ON position.
   (5) Do again the operational test of the EIU with the CFDS to confirm this fault AMM 73-25-34-710-802.
4. Fault Isolation
WARNING: MAKE SURE THAT THE CIRCUIT BREAKERS ARE OPEN BEFORE YOU DO MAINTENANCE WORK ON THIS SYSTEM WIRING. THE VOLTAGE ON THIS SYSTEM IS DANGEROUSLY HIGH AND CAN CAUSE SEVERE INJURY.
Subtask 73-25-00-810-325-A ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
   (1) Replace EIU-2 [1KS2] AMM 73-25-34-000-802 and AMM 73-25-34-400-802.
   (2) Do the test given in Para. 3. with the ENG/MASTER Control Switch (2KC) in the position that confirmed the fault.
   (3) If the fault continues:
     (a) Troubleshoot as follows:
   (4) Check on report for any failure of BUS bars (204XP) and (401XP).
     (a) Troubleshoot as necessary (Ref. TSM Chap. 24).
     (b) Do the test given in the Para. 3. with the ENG/MASTER control switch (2KC) in the position that confirmed the fault.
     (c) If no fault regarding the BUS bar is reported or if fault continues, go to the Para. 4.C.
Subtask 73-25-00-865-096-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2)
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
121VUENGINE/IGN/ENG2/SYS B3JH2P42
Subtask 73-25-00-810-326-A ** ON A/C NOT FOR ALL
C. If no fault regarding the BUS bar is reported or if fault continues:
   (1) Remove EIU-2 [1KS2] AMM 73-25-34-000-802.
   (2) Use a MULTIMETER - STANDARD to test the 115 VAC supply circuits AWM 743101 and AWM 743102. Refer to Table 1 and Table 2. Look for:
     (a) Wire-to-wire shorts
     (b) Shorts to ground
     (c) Continuity (less than 5 ohms resistance).
NOTE: A short to ground is found when the resistance is less than 100 000 (100K) ohms.
Table 1: Ignitor System A Circuit Connector Contacts
C/B (1JH) Contacts
EIU-2 (1KS2) Connector AC Contacts
2
4

Table 2: Ignitor System B Circuit Connector Contacts
C/B (3JH2) Contacts
EIU-2 (1KS2) Connector AC Contacts
2
13
   (3) If a problem is found:
     (a) Repair or replace aircraft wiring AWM 743101 and AWM 743102.
   (4) If no problem is found or if fault continues:
     (a) Replace EIU-2 [1KS2] AMM 73-25-34-400-802.
     (b) Go to the Para. 5.B.
     (c) Do the test given in the Para. 3. with the ENG/MASTER control switch (2KC) in the OFF position.
5. Close-up
Subtask 73-25-00-860-089-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
Subtask 73-25-00-865-097-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2)
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
121VUENGINE/IGN/ENG2/SYS B3JH2P42
Subtask 73-25-00-860-402-A ** ON A/C NOT FOR ALL
C. Put the aircraft back to its initial configuration.
   (1) Make sure the ENG/MASTER control switch (2KC) is in the OFF position.