W DOC AIRBUS | TSM A320F

Master Lever Fault on EIU-2


TASK 73-25-00-810-A23-A
Master Lever Fault on EIU-2


1. Possible Causes
  • EIU-2 [1KS2]
  • CTL SW-ENG/MASTER 2 [2KC]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AWM 732512
AMM 73-25-34-000-802
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-802
Installation of the Engine Interface Unit (EIU)
AMM 73-25-34-710-802
Operational Test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS)
AMM 73-25-34-860-806
Engine Interface Unit (EIU) DISCRETE INPUTS Menu Data Status
3. Fault Confirmation
Subtask 73-25-00-710-460-A ** ON A/C NOT FOR ALL
A. Do the test as follows:
   (1) On ENG panel 115VU, make sure that the ENG/MODE/CRANK/AUTO IGN/IGN selector switch (6KS) is in NORM position.
   (2) Put the ENG/MASTER 2 control switch (2KC) in ON position.
   (3) Do the operational test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS) to confirm this fault AMM 73-25-34-710-802.
     (a) Return to CFDS menu.
   (4) Put the ENG/MASTER 2 control switch (2KC) in OFF position.
   (5) Do the operational test of the EIU with the CFDS to confirm this fault AMM 73-25-34-710-802.
   (6) Record the ENG/MASTER 2 control switch position (ON or OFF) that confirms the fault.
4. Fault Isolation
Subtask 73-25-00-810-292-A ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
   (1) On ENG panel 115VU, make sure that the ENG/MODE/CRANK/AUTO IGN/IGN selector switch (6KS) is in NORM position.
   (2) Put the ENG/MASTER 2 control switch in position recorded in the Para. 3.A.(6).
   (3) Check the status of the EIU-2 discrete input for ENG MASTER SW ON and ENG MASTER SW OFF AMM 73-25-34-860-806.
   (4) If the ENG/MASTER 2 control switch (2KC) is in ON position, the status of discrete input:
     (a) ENG MASTER SW ON must be equal to 1.
     (b) ENG MASTER SW OFF must be equal to 0.
     (c) If both statuses are correct:
       1 Replace EIU-2 [1KS2] AMM 73-25-34-000-802 and AMM 73-25-34-400-802.
       2 Do the test given in Para. 3.
     (d) If one status is not correct:
       1 Remove EIU-2 [1KS2] AMM 73-25-34-000-802.
       2 Remove the ENG/MASTER 2 control switch (2KC).
       3 If ENG MASTER SW ON is equal to 0, check wiring between EIU-2 (1KS2) connector AA pin 4E and ENG/MASTER 2 control switch (2KC) pin 2A for continuity AWM 732512.
       4 If there is no continuity, repair/replace wiring.
       5 If there is continuity:
         a Replace CTL SW-ENG/MASTER 2 [2KC] AWM 732512.
       6 If ENG MASTER SW OFF is equal to 1, check wiring between EIU-2 (1KS2) connector AA pin 5A and ENG/MASTER 2 control switch (2KC) pin 3A for wire-to-wire short or short to ground AWM 732512.
       7 If wiring is not OK, repair/replace wiring.
       8 If wiring is OK, replace CTL SW-ENG/MASTER 2 [2KC] AWM 732512.
       9 Do the test given in Para. 3.
   (5) If the ENG/MASTER 2 control switch (2KC) is in OFF position, the status of discrete input:
     (a) ENG MASTER SW ON must be equal to 0.
     (b) ENG MASTER SW OFF must be equal to 1.
     (c) If both statuses are correct:
       1 Replace EIU-2 [1KS2] AMM 73-25-34-000-802 and AMM 73-25-34-400-802.
         a Do the test given in Para. 3.
     (d) If one status is not correct:
       1 Remove EIU-2 [1KS2] AMM 73-25-34-000-802.
       2 Remove the ENG/MASTER 2 control switch (2KC).
       3 If ENG MASTER SW OFF is equal to 0, check wiring between EIU-2 (1KS2) connector AA pin 5E and ENG/MASTER 2 control switch (2KC) pin 3A for continuity AWM 732512.
       4 If there is no continuity, repair/replace wiring.
       5 If there is continuity:
         a Replace CTL SW-ENG/MASTER 2 [2KC] AWM 732512.
       6 If ENG MASTER SW ON is equal to 1, check wiring between EIU-2 (1KS2) connector AA pin 4A and ENG/MASTER 2 control switch (2KC) pin 2A for wire-to-wire short or short to ground AWM 732512.
       7 If wiring is not OK, repair/replace wiring.
       8 If wiring is OK, replace CTL SW-ENG/MASTER 2 [2KC] AWM 732512.
       9 Do the test given in Para. 3.
   (6) If the fault continues:
     (a) Replace EIU-2 [1KS2] AMM 73-25-34-000-802 and AMM 73-25-34-400-802.
     (b) Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:36:27 UTC