W DOC AIRBUS | TSM A320F

Engine 1 Version Fault or Disagree


TASK 73-25-00-810-A02-A
Engine 1 Version Fault or Disagree


1. Possible Causes
  • Aircraft wiring
  • EIU-1 [1KS1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AWM 732503
AMM 73-25-34-000-802
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-802
Installation of the Engine Interface Unit (EIU)
AMM 73-25-34-710-802
Operational Test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS)
AMM 73-25-34-860-806
Engine Interface Unit (EIU) DISCRETE INPUTS Menu Data Status
3. Fault Confirmation
Subtask 73-25-00-710-437-A ** ON A/C NOT FOR ALL
A. Do the operational test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS) to confirm this fault AMM 73-25-34-710-802.
4. Fault Isolation
Subtask 73-25-00-810-261-A ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
   (1) Check the status of EIU-1 discrete input for engine version AMM 73-25-34-860-806.
     (a) Check that status of ENG VERSION LEAP 1A is 0.
     (b) Check that status of ENG VERSION GTF is 1.
     (c) If any status is not correct, remove the EIU-1 AMM 73-25-34-000-802.
       1 At connector AA, check for ground at pin 3E.
       2 Check that pin 3D is not used.
       3 Repair the Aircraft wiring as necessary AWM 732503.
       4 Do the test given in Para. 3.
     (d) If status are correct or if fault continues:
       1 Replace EIU-1 [1KS1] AMM 73-25-34-000-802 and AMM 73-25-34-400-802.
       2 Do the test given in Para. 3.
5. Close-up
Subtask 73-25-00-860-066-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:36:25 UTC