W DOC AIRBUS | TSM A320F

Loss of Data on the ARINC Bus from the EIU to the FADEC on Engine 1


TASK 73-25-00-810-936-A
Loss of Data on the ARINC Bus from the EIU to the FADEC on Engine 1


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 73-21-60-000-001
Removal of the Electronic Control Unit (ECU)
AMM 73-21-60-400-001
Installation of the Electronic Control Unit (ECU)
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
3. Fault Confirmation
Subtask 73-25-00-710-327-A ** ON A/C NOT FOR ALL
A. Test
   (1) Not applicable.
4. Fault Isolation
Subtask 73-25-00-810-192-A ** ON A/C NOT FOR ALL
A. Replace the EIU-1 [1KS1] AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
   (1) If the fault continues:
Subtask 73-25-00-810-192-B ** ON A/C NOT FOR ALL
A. Replace the EIU-1 [1KS1] AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
   (1) If the fault continues:
Subtask 73-25-00-710-328-A ** ON A/C NOT FOR ALL
B. No additional maintenance action is required if the fault is not confirmed.
   (1) Repeat the fault isolation procedure if the fault continues.
[Rev.8 from Aug 2018] 2026.04.04 04:35:49 UTC