W DOC AIRBUS | TSM A320F

Loss of Data on the ARINC Bus from the EIU to the FADEC on Engine 2


TASK 73-25-00-810-900-A
Loss of Data on the ARINC Bus from the EIU to the FADEC on Engine 2


1. Possible Causes
  • harness J3 between the EIU-2 (1KS2) and the ECU (4000KS)
  • EIU-2 [1KS2]
  • ZONE CONTROLLER [8HK]
  • ECU [4000KS]
  • CONT-AIR COND SYSTEM 1 [47HH]
  • CONT-AIR COND SYSTEM 2 [57HH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
AMM 21-63-34-000-001
Removal of the Zone Controller
AMM 21-63-34-400-001
Installation of the Zone Controller
AMM 73-21-60-000-001
Removal of the Electronic Control Unit (ECU)
AMM 73-21-60-400-001
Installation of the Electronic Control Unit (ECU)
ASM 732506
AMM 73-25-34-000-040
Removal of the Engine Interface Unit (EIU)
AMM 73-25-34-400-040
Installation of the Engine Interface Unit (EIU)
AMM 73-29-00-710-040
Operational Test of the FADEC on the ground (with Engine Motoring)
3. Fault Confirmation
Subtask 73-25-00-710-248-A ** ON A/C NOT FOR ALL
A. Do the operational test of the FADEC 2A on the ground (with engine non motoring) AMM 73-29-00-710-040.
4. Fault Isolation
Subtask 73-25-00-810-151-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message EIU (227), J3:
  • do a check for open or short to ground of the harness J3 between the EIU-2 (1KS2) and the ECU (4000KS) pins AB/5A, 5C to pins J3/22, 23 ASM 732506.
   (1) If the wiring is not correct:
  • repair the above wiring.
   (2) If the wiring is correct:
   (3) If the fault continues:
   (4) If the fault continues:
Subtask 73-25-00-810-151-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CFDIU, EIU (227), J3*:
  • do a check for open or short to ground of the harness J3 between the EIU-2 (1KS2) and the ECU (4000KS) pins AB/5A, 5C to pins J3/22, 23 ASM 732506.
   (1) If the wiring is not correct:
  • repair the above wiring.
   (2) If the wiring is correct:
   (3) If the fault continues:
   (4) If the fault continues:
Subtask 73-25-00-810-151-E ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message EIU (227), J3:
  • do a check for open or short to ground of the harness J3 between the EIU-2 (1KS2) and the ECU (4000KS) pins AB/5A, 5C to pins J3/22, 23 ASM 732506.
   (1) If the wiring is not correct:
  • repair the above wiring.
   (2) If the wiring is correct:
   (3) If the fault continues:
   (4) If the fault continues:
Subtask 73-25-00-710-249-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:35:48 UTC