Loss of Data on the ARINC Bus from the EIU to the FADEC on Engine 1
TASK 73-25-00-810-897-A
Loss of Data on the ARINC Bus from the EIU to the FADEC on Engine 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 73-25-00-710-242-A ** ON A/C NOT FOR ALL
Subtask 73-25-00-810-148-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:35:47 UTC
Loss of Data on the ARINC Bus from the EIU to the FADEC on Engine 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 73-21-60-000-001 | Removal of the Electronic Control Unit (ECU) |
| AMM 73-21-60-400-001 | Installation of the Electronic Control Unit (ECU) |
| AMM 73-25-34-000-040 | Removal of the Engine Interface Unit (EIU) |
| AMM 73-25-34-400-040 | Installation of the Engine Interface Unit (EIU) |
| AMM 73-29-00-710-040 | Operational Test of the FADEC on the ground (with Engine Motoring) |
Subtask 73-25-00-710-242-A ** ON A/C NOT FOR ALL
A. Do the operational test of the FADEC 1A on the ground (with engine non motoring) AMM 73-29-00-710-040.
4. Fault IsolationSubtask 73-25-00-810-148-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message EIU (031), J3:
Subtask 73-25-00-710-243-A ** ON A/C NOT FOR ALL - replace the EIU-1 [1KS1] AMM 73-25-34-000-040 and AMM 73-25-34-400-040.
- replace the ECU [4000KS] AMM 73-21-60-000-001 and AMM 73-21-60-400-001.
B. Do the test given in Para. 3.A.
(1) No additional maintenance action is required if the fault is not confirmed.
(2) Repeat the fault isolation procedure if the fault continues.
(1) No additional maintenance action is required if the fault is not confirmed.
(2) Repeat the fault isolation procedure if the fault continues.